Installation
Instructions
DUCTWORK INSTALLATION
(Note:
For planning
purposes
only.)
[] INSTALLING
THE DUCTWORK
Use galvanized
or aluminum
duct in 6" round
or 31/4 " x 10" size, or a combination
of both.
PVC duct should
be used if installing
under
a
poured
concrete
slab.
NOTE: Local
building
code
must
be followed
in specifying
approved
type and schedule
of
ALL duct
used.
Always
use an appropriate
roof
or wall
cap
with
damper.
Laundry-type
wall
caps should
NEVER be used.
Through
Cabinet
Toe Space
Between Floor Joist
Downward
Venting
Install
ductwork,
making
male-female
connections
in the direction
of airflow
as
shown.
Secure
all joints
with
sheet
metal
screws
and duct tape to assure
an airtight
seal.
Duct
Tape
Over
Seam
--
and Screw
Screw
Use the shortest
and straightest
duct run
possible.
For satisfactory
performance,
the
duct run should
not exceed
100 feet
equivalent
length.
Refer to TABLE
1 of
equivalent
lengths.
Use TABLE
1 to calculate
the total
equivalent
length
of the ductwork.
OPTIONAL
INSTALLATION:
REAR WALL VENTING
5" round
duct may
be used on SHORT
DUCT
runs of 3 feet or less, such as direct
to outside
wall
venting.
Inside Wall to Roof
Direct to Outside
Rear Wall Venting
To convert
blower
exhaust
direction,
remove
four
nuts behind
the filter which
hold blower
and wire
finger
guard.
Rotate
blower
and reinstall
to vent
chamber,
as shown
above.
Retighten
nuts,
but do not
overtighten.