English
Nails are not be-
The Piston Cushion
ing counter sunk
(Ref. #10) could be
into wood and
damaged prevent-
are left sticking
ing the Piston (Ref.
out of wood.
#56) from complet-
(cont.)
ing full stroke.
Nailer does not
This is a safety
operate when
feature
trigger is pulled.
Ram is stuck in
Air pressure too
down position
low.
Driver Blade (Ref.
#58) could be bent
Oil could have been
used in the tool
Cylinder Cushion
Ring (Ref. #5) could
be loose or dam-
aged or has been
installed upside
down.
Tool partially
Main Valve (Ref.
operates when
#41) is not seating
air hose is con-
in Valve Housing
nected
(Ref. #46).
O-Rings on the
Discharge Valve
(Ref. #11) may be
damaged.
Discharge Valve
Springs (Ref. #9)
not aligned
Cylinder Exhaust
Valve Screw (Ref.
#50) may be loose.
Nailer partially
Main Valve Lip Seal
operates when
(Ref. #41) is not
trigger is pulled
sealing
and before Ram
is struck
Contact Hitachi for replace-
ment.
The Nailer is not supposed
to operate when the Trigger
is pulled. In order to operate
the Nailer, the Trigger must be
pulled and the Ram Head (Ref.
#47) tapped with the hammer,
in that order.
Set air pressure to 100-115 PSI
Contact Hitachi for replace-
ment.
Contact Hitachi for replace-
ment.
Contact Hitachi for replace-
ment.
Contact Hitachi for replace-
ment.
Contact Hitachi for replace-
ment.
Contact Hitachi for replace-
ment.
Contact Hitachi for replace-
ment.
Contact Hitachi for replace-
ment.
— 32 —