OPERATING THE
PAPR
CHECKING THE AIR FLOW
With the blower unit running place the Flow-Test-Unit onto the hose so that the sealing
gasket is securely gripping the air outlet. Check that the indicator ball rises above the pass
fail marker. This easy testing device is supplied with every AIRMAX® PAPR unit. Jackson
Safety recommends carrying out this operation at least at the beginning of every shift and
after changing the filter or any other cleaning or maintenance activity.
Activate the Power-Switch at the side of the unit. Once
turned on, the flow alarm activates for about 1 second
until the minimum flow rate is achieved and respiratory
protection is provided given that all components are in
place for the wearer to start the task.
The airflow can be adjusted by two arrow-buttons from
170 l/min up to 240 l/min. The number of lit Green LED
diodes shows the actual airflow level.
The blower should then provide an initial air flow of
+170 LPM for at least 8 hours at a comfortable noise
intensity of <70dB.