LABEL
MIN.
MAS.
C0
0
240
C2
0
240
C3
0
240
C4
0
240
C5
0
240
C6
0
199
C7
0
199
C8
0
15
LABEL
MIN.
MAS.
d0
0
99
d2
-99
99
d3
0
99
d4
0
1
d5
0
99
d6
0
2
d7
0
15
d8
0
3
d9
-99
99
d11
0
1
d16
0
999
d18
0
999
d19
0
40
d20
0
999
d22
0
19,9
LABEL
MIN.
MAS.
A1
0
99
A4
0
99
A6
0
99
A7
0
199
A11
0,1
15
LABEL
MIN.
MAS.
i0
0
4
i1
0
1
U.M.
COMPRESSOR PROTECTION SYSTEM
min
delay in switching on of compressor after the device switches on (4)
min
minimum compressor switch-off duration (5)
s
minimum duration of compressor switch on time
duration of compressor switch off time during a room temperature probe error (code "Pr1"); see also C5
min
duration of compressor switch on time during a room temperature probe error (code "Pr1"); see also C4
min
condenser temperature is higher than that at which the condenser overheating alarm is activated (code
°C/°F (1)
"COH") (6)
condenser temperature above which the compressor shut down alarm is activated (code "CSd")
°C/°F (1)
compressor shut down alarm delay (code "CSd") (7)
min
U.M.
DEFROST
if d8 = 0, 1 or 2, defrost interval
h
0 = interval defrost will never be activated
if d8 = 3, maximum defrost interval
°C/°F (1)
evaporator temperature at end of defrost; see also d3
if P4 = 0 or 2, defrost duration
min
if P4 = 1, maximum defrost duration; see also d2
0 = defrost will not be activated
defrost when device is switched on (4)
-
1 = YES
if d4 = 0, minimum time between switching on of device and activation of defrost (4)
min
if d4 = 1, delay in activation of defrost after device is switched on (4)
temperature displayed during defrost (only if P5 = 0)
0 = room temperature
1 = if on activation of defrost, the room temperature is below the "work setpoint + + Δt", at maximum "
-
work setpoint + Δt"; if on activation of defrost, the room temperature is above "work setpoint + Δt", at
maximum the room temperature on activation of defrost (8) (9)
2 = label "dEF"
min
dripping duration (during dripping the compressor will remain switched off)
defrost activation methods
0 = AT INTERVALS - FOR TIME - defrost will be activated once the device has altogether been
running for time d0
1 = AT INTERVALS - FOR COMPRESSOR SWITCH-ON - defrost will be activated once the
compressor has altogether been switched on for time d0
-
2 = AT INTERVALS - FOR EVAPORATOR TEMPERATURE - defrost will be activated when the
evaporator temperature has remained below the temperature d9 for a total time of d0 (10)
3 = ADAPTIVE - defrost will be activated at intervals, whose duration will each time depend on the
duration of compressor switch-ons, the evaporator temperature and the door switch input activation; see
also d18, d19, d20, d22, i13 and i14 (10)
evaporator temperature is higher than that at which the defrost interval counter is suspended (only if d8
°C/°F (1)
= 2)
defrost alarm switches off once maximum time limit has been reached (code "dFd"; only if P4 = 1 and
in absence of evaporator probe error (code "Pr2")
-
1 = YES
defrost interval (defrost will be activated when the compressor has been on totally, with the evaporator
min
temperature below that of d22, for time d18; only if d8 = 3)
0 = defrost will never be activated due to the effect of this condition
defrost interval (defrost will be activated when the compressor has been on totally, with the evap.
min
temp. below that of d22, for time d18; only if d8 = 3)
0 = defrost will never be activated due to the effect of this condition
evaporator temperature below which the defrost is activated (relative to the evaporator temperatures
°C/°F (1)
average, or "evaporator temperatures average - d19"; only if d8 = 3)
minimum consecutive time the compressor must be switched on such as to provoke the defrost
min
activation
0 = defrost will never be activated due to the effect of this condition
evaporator temperature above which the defrost interval count shall be suspended (relating to the
average of evaporator temperatures, that is to say, "evaporator temperatures average + d22"; only if
°C/°F (1)
d8 = 3); see also d18
U.M.
TEMPERATURE ALARMS (11) (12)
room temperature below which the minimum temperature alarm is triggered (code "AL"; it concerns the
°C/°F (1)
working setpoint, that is to say, "working setpoint - A1"); see also A11
0 = alarm absent
room temperature above which the maximum temperature alarm is triggered (code "AH"; it concerns
the working setpoint, that is to say, "working setpoint + A4"); see also A11
°C/°F (1)
0 = alarm absent
delay in maximum temperature alarm (code "AH") after the device is switched on (4)
10 min
min
minimum temperature alarm delay (code "AL") and maximum temperature alarm delay (code "AH")
°C/°F (1)
differential of A1 and A4 parameters
U.M.
DIGITAL INPUTS
-
effect caused by the activation of the digital input
0 = no effect
1 = DOOR SWITCH - DOOR SWITCH INPUT ALARM ACTIVATION (code "id") - the compressor will
be switched off (at maximum for time i3 or until the input is deactivated); see also i2 (13)
2 = MULTIFUNCTION - ACTIVATION OF "ENERGY SAVING" FUNCTION – the "energy saving"
function will be activated (just with effect on the compressor, until the input is deactivated); see also r4
3 = MULTIFUNCTION - ACTIVATION OF MULTIFUNCTION INPUT ALARM (code "iA") - the device
will continue to operate normally; see also i2
4 = MULTIFUNCTION - ACTIVATION OF THE MAXIMUM PRESSURE SWITCH ALARM (code "iA") -
the compressor will be switched off (until the input is deactivated); see also i2
type of digital input contact
-
0 = normally open (active input with closed contact)
1 = normally closed (active input with open contact)
14