• Touch the
or
• Touch the
To exit the procedure before the operation is complete:
• Touch the
(any changes will not be saved)
The working setpoint can also be set via SP parameter.
Working setpoints
LABEL
MIN.
MAS.
r1
r2
Setting the configuration parameters
To access the procedure:
• Make sure no procedure is in progress
• Touch the
• Touch the
• Touch the
or
default)
• Touch the
To select a parameter:
• Touch the
or
To set a parameter:
• Touch the
key
• Touch the
or
• Touch the
To exit the procedure:
• Touch the
Configuration parameters
LABEL
MIN.
MAS.
SP
r1
r2
LABEL
MIN.
MAS.
CA1
-25
25
CA2
-25
25
P0
0
1
P1
0
1
P2
0
1
P4
0
2
P5
0
2
P8
0
250
LABEL
MIN.
MAS.
r0
0.1
15
r1
-99
r2
r2
r1
99
r4
0
99
r5
0
1
r12
0
1
LABEL
MIN.
MAS.
C0
0
240
C2
0
240
C3
0
240
C4
0
240
C5
0
240
C6
0
199
C7
0
199
key within 15 s; see also r1 and r2 parameters
key or do not operate for 15 s: the LED
U.M.
WORKING SETPOINT
°C/°F (1)
working setpoint; see also r0 and r12
key for 4 s: the display will show "PA"
key within 15 s to set the value determined with the "PAS" parameter (the parameter is set at "-19" by
or do not operate for 15 s: the display will show "SP"
key
key within 15 s.
key or do not operate for 15 s.
key for 4 s or do not operate for 60 s (any changes will be saved)
U.M.
WORKING SETPOINT
°C/°F (1)
working setpoint; see also r0 and r12
U.M.
ANALOG INPUTS
°C/°F (1)
room probe offset
if P4 = 1, evaporator probe offset
°C/°F (1)
if P4 = 2, condenser probe offset
-
probe type (0 = PTC; 1 = NTC)
-
degree Celsius decimal point (during normal operation)
unit of measurement for temperature (2)
-
0 = °C (Celsius degree; resolution depends on P1 parameter)
1 = °F (Fahrenheit degree; resolution is 1 °F)
second input function
0 = digital input (door switch or multifunction)
-
1 = analog input (evaporator probe)
2 = analog input (condenser probe)
magnitude displayed during normal operation
0 = room temperature
1 = working setpoint
-
2 = if P4 = 0, "- - -"
if P4 = 1, evaporator temperature
if P4 = 2, condenser temperature
0,1s
delayed display of temperature changes as detected by the probes
U.M.
MAIN REGULATOR
°C/°F (1)
working setpoint differential; see also r12
°C/°F (1)
minimum working setpoint
°C/°F (1)
maximum working setpoint
working setpoint increase during the "energy saving" function; see also i0, i10 and HE2
°C/°F (1)
-
cooling or heating operation (3)
0 = cooling
1 = heating
-
working setpoint differential type
0 = asymmetric
1 = symmetric
U.M.
COMPRESSOR PROTECTION SYSTEM
min
delay in switching on of compressor after the device switches on (4)
min
minimum compressor switch-off duration (5)
s
minimum duration of compressor switch on time
duration of compressor switch off time during a room temperature probe error (code "Pr1"); see also C5
min
duration of compressor switch on time during a room temperature probe error (code "Pr1"); see also C4
min
condenser temperature is higher than that at which the condenser overheating alarm is activated (code
°C/°F (1)
"COH") (6)
condenser temperature above which the compressor shut down alarm is activated (code "CSd")
°C/°F (1)
will switch off after which, the device will exit the procedure.
13
1 = YES

Publicidad

Tabla de contenido
loading