General Cleaning And Maintenance - Sagi ME70LTR Manual De Uso E Instalación

Cabinas frigorificas
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 157
In case of working irregularities, before to call the technical service in zone verify that:
the main switch 1 is lighting and the current is present;
the regulated temperature is the wished one;
the doors are perfectly closed;
the machine is not near heat sources;
the condenser is clean and the fan works regularly;
an excess of hoarfrost does not cover the evaporating pannel.
In case of negative result, contact the nearest service centre indicating the model (1) and the serial number
(5) shown on the rating placed on the appliance instrument panel.

GENERAL CLEANING AND MAINTENANCE

For a constant efficiency of the refrigerator it is recommended to perform the cleaning and mantainance
operations.
Before to begin with the operations proceed as following:
set the general cut-out in OFF position
remove the plug from the socket and wait till the complete
entfrosting of the refrigerator.
Accurately clean the condenser in the refrigerating unit and the inner evaporator with
either a vacuum cleaner, a bristle brush or a non-wire brush after removing the
protections.
WARNING: The cleaning and mantainance of the refrigerating engine and the
compressor area needs the intervention of a skilled technician, therefore it cannot be
done by other persons.
Clean the external and internal surfaces with water and neutral soap or detergent; a
little vinegar in the water will remove eventual bad smells.
Rinse abundantly with pure water and dry up accurately.
The cleaning and mantainance operations have now come to end.