Command 44 Sets defrost cycle frequency:
This command sets the interval between defrost cycles expressed in hours. This value can be varied from 1h
and 8h and is preset at 4h.
N.B.: with the SPIRAL SLAVE connection enabled (see Command 49), after setting the MASTER machine,
the same parameters for the SLAVE machine can be set.
Command 45 Setting the cut-out duration for the refrigeration safety device:
This command sets the amount of time that the refrigeration safety device is to remain disabled. This period
of time prevents the vending machine from shutting down following an operation that involves having the
door open with the subsequent increase in the internal temperature. The delay in activating the refrigeration
unit safety device gives the machine time to return to its normal operating temperature. The value of this
command is preset at 60 min. but can be varied from 30 to 360 min.
N.B.: with the SPIRAL SLAVE connection enabled (see Command 49), after setting the MASTER machine,
the same parameters for the SLAVE machine can be set.
This option is only available on FASTER SLAVE vending machines
E
N
Command 46 Setting the trigger temperature for the refrigeration safety device:
G
This command sets the trigger temperature for the safety device, that is the temperature above which it
L
prevents the machine from vending the selected product (see Command 48). A warning message appears
I
on the display when the user attempts to make one of these selections. This control is disabled when the
S
machine is switched on and after the door is shut for a period of time set on command 45. The preset value
H
is +7°C but it can be changed to between +7°C and +35°C. When the refrigeration unit safety device trips,
the selections involved remain out of service. To reset the refrigeration unit safety device: with the door
open, the event that occurred on the master vending machine or on the slave machines connected to it,
appears on the display of the master vending machine. Press ENTER on the external keypad to reset the
device. If you press the ESC button or close the door, the action remains active and is recorded as ERROR
93. If the refrigeration unit safety device is still active when you close the door, an acoustic alarm (series of
BEEPS) will automatically begin to sound.
N.B.: with the SPIRAL SLAVE connection enabled (see Command 49), after setting the MASTER machine,
the same parameters for the SLAVE machine can be set.
This option is only available on FASTER SLAVE vending machines
Command 48 Setting trays with refrigeration safety device:
This command allows you to select which trays are subject to the refrigeration safety device. The command
requires a setting for each tray: enable safety device = 1, or disable safety device = 0. Tray 1 refers to the
top tray. By default, all the trays are set at 1.
N.B.: with the SPIRAL SLAVE connection enabled (see Command 49), after setting the MASTER machine,
the same parameters for the SLAVE machine can be set.
This option is only available on FASTER SLAVE vending machines
www.vendival.com
The products must be introduced at the correct temperature for preservation as specified
by the regulations in force. The non-observance of this regulation could activate the
"refrigeration safety device".
For detailed descriptions on the reloading modes, see paragraph "GUIDELINES FOR
LOADING PRODUCTS"
For the machine to function correctly the drawers to be set with the refrigeration unit safety
device
must
be
located
CHARACTERISTICS).
inside
the
3°C
area
Telf. 902 07 07 59 - Whatsapp 615 35 50 96
FASTER – Issue 02
(see
paragr.
TECHNICAL