Descargar Imprimir esta página

MSW Motor Technics MSW-PLT-W20 Manual De Instrucciones página 42

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 127
Remove any remains with a specialist ash vacuum cleaner.
When inserting the ash container, make sure that it fits accurately and tightly.
Otherwise, the sensor may detect the absence of the container and turn the stove off
as a result.
q)
Recommended standard cleaning intervals:
Hearth - after each 5 bags of pellets
Ash container - after each 10 bags
Exhaust fan - after each 100 bags
Blowing air fan - after each 50 bags
Remove the used batteries from the remote control in the same way as you installed them.
Return the batteries to a unit responsible for their disposal.
DISPOSAL OF WASTE APPLIANCES
At the end of its useful life, this product should not be disposed of with normal household waste
but should be taken to a collection point for the recycling of electrical and electronic equipment.
This is indicated by the symbol on the product, operating instructions or packaging. The materials
used in this appliance are recyclable according to their marking. By reuse, recycling or applying
other forms of use of waste machines, you make a significant contribution to the protection of
our environment.
Your local administration will provide you with information about the appropriate disposal point
for used appliances.
Troubleshooting
The list contains common problems with the device. Before contacting the manufacturer's service, it
is recommended to check whether the problem can be solved by yourself.
Problem
1. When the power is turned on,
the power light is not on or the
control panel does not display data.
2. After turning on the stove, the
blower fan does not work.
3. The feeding screw does not feed
pellets. No power 20 seconds after
first power on.
EN
Reason
No power to the stove or
control panel.
The fuse is damaged.
When the control system
detects that the ignition is
successful, the device will
automatically start working.
this is a normal
phenomenon.
The auger tube is blocked.
There is a problem with the
connection between the
feed motor and the auger.
No pellets in the tank.
Solution
Check power and cables.
Replace the fuse on the
motherboard.
Please wait a while.
Clean the auger tube, use standard
pellets.
Check whether the screws
between the feed screw and the
motor are loose or misaligned. If
so, repair or replace it.
Add pellets to the tank

Publicidad

loading