7. DIGITAL THERMOSTAT
Button
Normal operation
Single pressing button
UP
Single button pressing –
ON/
setting the parameters
OFF
„upward".
(turning
Pressing for more than
on /
3 seconds – switching
turning
between ON/OFF (ON –
off)
device in normal opera-
tion, OFF – device is tur-
ned off, the temperature
regulation and defrosting
are turned off.
DOWN
Single button pressing –
Defrost
setting the parameters
„downward".
Pressing for more than 3
seconds – turning on and
off the defrosting mode.
SET
Button pressed for 1 se-
MUTE
cond: setting the desired
set point.
Button pressed for more
than 3 seconds: entering
the setup menu.
Turning off the alarm
(mute).
NOTE! If any change in the setup menu is needed, please contact your service agent
or qualified Technician.
26
Start up
Pressing
together
buttons
Buttons
pressed
together:
activating
/ deac-
tivating
conti-
nuous
cycle
Pressing
Button
buttons
pressed for 1
to-
second: dis-
gether:
play showing
– start
the firmware
of the
version code.
parame-
Button
ter reset
pressed for
proce-
1 second –
dure.
resetting the
current EZY
(easy con-
figuration)
setting.
LED display symbols
Symbol Function
Normal operation
ON
Compres-
On
sor
Fan
On
Defrost
On
Aux
Output on
Alarm
All
Clock
RTC fitted and
enabled, at least 1
time band set
8. TECHNICAL DATA
Item
RCKT-140/70-V RCKT-137/70-G
Art. No
1454
Rated input power
300 W
Rated current
2,0 A
Power consumption
4,5 kWh / 24 h
Refrigerant
R134a (260 g)
Work temperature
Rated frequency:
Rated voltage
Volume
380 L
Temperature
Electric shock protec-
tion class
Start up
OFF
BLINKING
Off
Request
ON
Off
Request
ON
Off
Request
ON
Output off
-
ON
No alarm
-
ON
RTC not fitted
-
ON if
or disabled, not
RTC
even 1 time
fitted
band set
RCKT-90/70-G
1453
1450
300 W
250 W
2,0 A
1,7 A
4,5 kWh / 24 h
4,5 kWh / 24 h
R134a (260 g)
R134a (200 g)
From 10⁰C to 32⁰C
50 Hz
230 V
380 L
300 L
From 0⁰C to +10⁰C
I
27