Power
2 Ensure the Safety Reversing Sensors are Aligned
The door will not close if the sensors have not been installed and aligned correctly.
When the light beam is obstructed or misaligned while the door is closing, the door will reverse and the
garage door opener lights will flash ten times. If the door is already open, it will not close. The sensors
can be aligned by loosening the wing nuts, aligning the sensors, and tightening the wing nuts.
1. Check to make sure the LEDs in both sensors are glowing steadily. The LEDs in both sensors
will glow steadily if they are aligned and wired correctly.
(invisible light beam)
Amber LED
SENDING SENSOR
If the receiving sensor is in direct sunlight,
switch it with sending sensor so it is on the
opposite side of the door.
Green LED
RECEIVING SENSOR
IF THE AMBER LED ON THE SENDING SENSOR IS NOT GLOWING:
1. Make sure there is power to the garage door opener.
2. Make sure the sensor wire is not shorted/broken.
3. Make sure the sensor has been wired correctly: White wires to white terminal and white/black
wires to gray terminal.
1
IF THE GREEN LED ON THE RECEIVING SENSOR IS NOT GLOWING:
1. Make sure the sensor wire is not shorted/broken.
2. Make sure the senors are aligned.
1
2
3 Ensure the Door Control is Wired Correctly
If the door control has been installed and wired correctly, the command LED behind the push bar will
blink.
21
3
2