MENU → SETTINGS
→ Installation con-
figuration
→ Screed drying
→ Change code
→ Language, time, display
→ Language:
→ Date:
→ Time:
→ Display brightness:
→ Daylight saving
time:
For outdoor temperature sensors with DCF77 receivers, the Daylight saving time: function
is not used. The conversion to summer/winter time takes place via the DCF77 signal. The
change takes place:
– On the last weekend in March at 02:00 (daylight saving time)
– On the last weekend in October at 03:00 (standard time)
→ Offset
→ Room temperat-
ure: K
→ Outdoor temper-
ature: K
→ Factory settings
2.11.4
-- Installation configuration menu item
MENU → SETTINGS → Installer level → Installation configuration
→ Installation
→ Water pressure: bar
→ eBUS components
→ Adaptive heat curve:
12
Functions (→ Installation configuration menu item)
Activate the Screed drying profile function for freshly laid screed in
accordance with the construction regulations.
The control regulates the flow temperature independently of the out-
door temperature. Setting screed drying (→ Installation configuration
menu item)
After the power is switched off, the date is retained for approx. 30
minutes.
After the power is switched off, the time is retained for approx. 30
minutes.
→ Automatic
→ Manual
Comparison of the temperature difference between the measured
value in the control and the value for a reference thermometer in the
living room.
Comparison of the temperature difference between the measured
value in the outdoor temperature sensor and the value for a reference
thermometer in the living room.
The control resets all of the settings to the factory settings and calls up
the installation assistant.
Only the competent person can call up the installation assistant.
List of eBUS components and their software versions
Automatic fine adjustment of the heat curve. Prerequisite:
– The suitable heat curve for the building is set in the Heat
curve: function.
– The correct zone is assigned to the control in the Zone
assignment: function.
– Expanded is selected in the Room temp. mod.: func-
tion.
Operating and installation instructions 0020323648_01