GENERAL NOTES
In Italy it is necessary to refer to the standard declaration of
conformity conforming to Ministerial Decree 37/2008 (pur-
suant to Law 46/1990) and standards UNI 10683/2012 and UNI
10412-2/2009.
In the case of installation in a multiple-tenancy building, con-
tact the building manager before installation.
In France, it is necessary to refer to Decree
VERIFY COMPATIBILITY WITH OTHER DEVICES
In Italy the insert MUST NOT be installed in the same space
as type B gas heating equipment (e.g. gas boilers, stoves, and
equipment served by an extraction hood - ref. UNI 10683 and
7129).
In general, the insert could create low pressure in the room,
affecting the operation of such appliances or being affected by
them.
VERIFYTHE POWER SUPPLY CONNECTION
(the plug must be accessible)
The insert is supplied with a power cable that is to be con-
nected to a 230V 50 Hz socket, preferably fi tted with a magne-
tothermic switch.
The electrical system must comply with the law; particularly
verify the effi ciency of the earthing system. The power line
must have a suitable cross-section for the insert's power. An
inadequate earthing system can cause anomalies for which
Edilkamin cannot be held liable.
Power variations greater than 10% can cause problems for the
product.
AIR INTAKE (NON-AIRTIGHT INSTALLATION)
An air intake must be prepared behind the insert and connected
with the outside.
It must have a useful minimum section of 80 cm² to guarantee
suffi cient air to the insert for combustion, without creating
depression in the installation room.
A 4 cm diameter outlet is found on the rear of the PELLKA-
MIN 10.
This outlet is used for air intake connected directly with the
outside via pipes.
The pipes must not be longer than 1 metre and have no bends
and must have a wind guard at the end.
INSTALLAZIONE
POSITIONING AND DISTANCES FOR FIRE SAFETY
To function correctly, PELLKAMIN 10 must be positioned on
the level.
Check that the fl oor load capacity is suffi cient.
PELLKAMIN 10 must be installed in compliance with the
following safety conditions:
- minimum distance from fl ammable materials around the sides
2008-1231.
and back of the insert: 20 cm
- fl ammable materials must not be placed less than 80 cm from
the front of the insert.
If it is not possible to comply with the above-mentioned di-
stances, technical and construction-related provisions must be
taken to prevent fi re hazards.
If connected to wooden walls or other fl ammable materials, the
smoke exhaust pipe must be insulated.
- 39
-