N.B.: IMPORTANT FOR INSTALLATION CONDITIONS
*
Provide two aeration grilles (area larger than 100 cm
fi rst one under the insert and the second positioned at least 50
cm above the insert or anyway communicating with the internal
compartment where the insert is positioned.
These grilles prevent the accumulation of heat inside, which is
then used to help heat the room of installation.
NOTES ON FITTING THE COVERING
In using a prefabricated Edilkamin covering, to identify the
exact position of PELLKAMIN 10 is important to verify the
model of the covering to be used.
Positioning differs according to the model chosen (see as-
sembly instructions given in the packaging of each covering).
Always check that installation is perfectly vertical and horizon-
tal.
COVERINGS, COUNTER-HOODS AND THEIR
VENTILATION
Before installing the covering, check that all connections, com-
mands and moving parts are perfectly functional.
Check this with the insert on and working for a few hours. Do
so prior to fi tting the covering in order to intervene as necessa-
ry.
Finishing works, such as construction of the counter-hood,
covering assembly, pilaster preparation, painting, etc.,
should be carried out once the fi nal test has been passed.
Edilkamin will therefore not be held liable for any charges
deriving from both demolition and reconstruction works,
even where consequent to replacement of any faulty insert
parts.
METAL PROFILE FINISHING PLATE (X) FOR
MOUNTING OF "FRAME" COVERINGS
(supplied)
After removing the lower grille, you can mount, on the lower
base of the structure, the "angular" metal fi nishing profi le (X
– for "frame" coverings or plasterboard) in place of the metal
profi le plate (Y) previously mounted (see Fig. 24).
INSTALLATION
fi g. 23
2
), the
External
intake
Rather, at least 1 cm. (approx.) space must be left to allow
air to fl ow, thereby preventing heat from accumulating.
The counter-hood can be created from fi reproof plaster-
board panels or plaster sheets. When creating this, the air
circulation grill must be included, as previously specifi ed.
- THE MANTEL CAN BE CONSTRUCTED WITH FIRE
RESISTANT PANELS IN PLASTERBOARD OR
GYPSUM BOARD.
- AERATION GRILLES FOR PREVENTING ANY
EXCESS TEMPERATURE INSIDE MUST BE PROVI-
DED FOR DURING CONSTRUCTION (fi g. 23).
During the construction phase of the covering it is funda-
mental to ensure that the combustion air is restored
to prevent pressure phenomena in the room where the
fi replace is installed (refer to the Chapter regarding the
external air inlet on page 40)
In addition to the above, always consider the indications
given by paragraphs 4.4 and 4.7 of standard UNI 10683
"insulation, fi nishes, coverings and safety recommenda-
tions".
fi g. 24
- 48
-
*
Internal mantel
ventilation grilled
*
Recycled air
intake inspection
X
Y