EN
17 Technical Data
Ref. no.:
Dimensions (width x height x depth):
Weight:
Power supply:
Maximum allowed impedance Zmax for power supply:
Refrigerant extraction rate:
Vacuum pump output:
Refrigerant recovery ratio:
Hermetic compressor output:
Drier filter output:
Vacuum pump oil service life:
Filling cylinder accumulator capacity:
Noise emission*:
Accuracy of the electronic scale for refrigerant:
Accuracy of the electronic scale for old/new oil:
Accuracy of the electronic scale for UV additive:
Maximum permissible pressure:
Refrigerant:
Oil:
Maximum permissible operating temperature:
Storage temperature range:
Ref. no.:
Dimensions (width x height x depth):
Weight:
Power supply:
Maximum allowed impedance Zmax for power supply:
Vacuum pump output:
Refrigerant recovery ratio:
Hermetic compressor output:
Drier filter output:
Vacuum pump oil service life:
Filling cylinder accumulator capacity:
Noise emission*:
Accuracy of the electronic scale for refrigerant:
Accuracy of the electronic scale for old/new oil:
Accuracy of the electronic scale for UV additive:
Maximum permissible pressure:
Refrigerant:
40
ASC 6300 G
9103303105
560 mm × 1300 mm × 650 mm
110 kg
230 V / 240 V, 50 Hz / 60 Hz
An inverter or similar device may be required to provide the
correct voltage.
0.43 Ω
30 kg/h
5 cars per hour
Minimum 95 %
0.32 kW
150 kg
60 h
16 kg
62 dB(A)
± 10 g
± 1 g
± 1 g
– 1 bar ... 20 bar
R134a, R1234yf, R513A
Only oil approved by manufacturer
5 °C ... 40 °C
25 °C ... 50 °C
ASC 6400 G
9103303106
560 mm × 1300 mm × 650 mm
110 kg
230 V / 240 V, 50 Hz / 60 Hz
An inverter or similar device may be required to provide the
correct voltage.
0.43 Ω
192 l/hr
Minimum 95 %
0.32 kW
150 kg
60 h
28 kg
62 dB(A)
± 10 g
± 1 g
± 1 g
– 1 bar ... 20 bar
R134a, R1234yf, R513A