Abus FUBE50000 Manual De Instalación Y Usuario página 38

Ocultar thumbs Ver también para FUBE50000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 147
Installation and start-up
Automatic calibration of the chip key reader
If the DIP switch 6 (chip key reader) is activated when the control device starts up,
calibration will be performed automatically as soon as the LED test is completed and the
software version is displayed.
During the calibration of the chip key reader, the status LEDs for sub-areas
1 to 4 light up one after the other (sequence of lights from top to bottom).
If DIP switch 6 (chip key reader) is deactivated when the control panel starts up,
calibration will be performed as soon as the DIP switch is activated.
The chip key reader re-calibrates itself automatically every 24 hours to
compensate for changes to the environmental conditions and to ensure
correct functioning.
Manual calibration of the chip key reader
You can also start the calibration manually by pressing the
simultaneously. This is required whenever changes to environmental conditions are
impeding the chip key reader's functions.
Keep the chip key and any other metal objects away from the chip key
reader during calibration to avoid disrupting the process.
38
and
keys

Publicidad

Tabla de contenido
loading

Tabla de contenido