Maintenance - Abus FUBE50000 Manual De Instalación Y Usuario

Ocultar thumbs Ver también para FUBE50000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 147

Maintenance

The wireless control device batteries usually have a lifespan of around two years.
If the batteries need to be replaced, the alarm control panel will display the error
message "FKBDT == batt low". In this case, the batteries should be replaced by
an installer.
The keys of the control device must undergo functional testing every year; the device
must also be cleaned.
Make sure that the system is not operating before carrying out the functional testing
for the keys.
In installer mode, select "Test  wireless control devices  wireless control device 01-08".
Select the wireless control device required. The display now shows "Press key to test".
Press the keys on the control device as follows in order to test them:
 Press 4 or 6 (numerical) buttons on the keypad in sequence, followed by a function
button: The display now shows the keys that were pressed – e.g. "1234A".
A =
 Press both fire, hold up, medical or social care buttons simultaneously to test
the manual trigger function of alarms. The display now shows the respective
abbreviations.
F =
Clean the outside of the housing with a soft, dry cloth. Do not use water or any form
of solvent or cleaning agent.
B =
C =
P =
M =
Maintenance
D =
H =
45

Publicidad

Tabla de contenido
loading

Tabla de contenido