ADJUSTMENT OF THE POWER AND OPERATIONAL TIMES

The power and operating times may be adjusted by means of 4 trimmers located on the control unit:
POWER:
motor power.
WORK:
motor operating time (2 - 50 seconds).
PLEASE NOTE: it is recommended that operating times be set with the slow down function disabled
(DIP 5 OFF).
WARNING: the adjustment of times has to be made when the gate is still
PAUSE:
pause time before automatic re-closure (2 - 150 seconds).
DELAY:
time delay between the two gate leaves (0 - 90 seconds).

CONTROL UNIT INDICATORS (LEDS)

The highlighted boxes indicate the state of the LEDs when the gate is resting.
LED
START
IN2
STOP
PHOTO
EDGE input closed (edge not pressed)
EDGE
EDGE input closed (edge pressed)
Edge NO pressed: 8K2 between EDGE input
mains
overload
Accessory power supply overload
ON
START input closed
START P. input closed
STOP input closed
PHOTO input closed
and common (-)
Control unit powered-up
Standard edge
EDGE input open (edge pressed)
Resistive rubber edge
EDGE input open (fault)
Control unit NOT powered-up
Accessory power supply within normal
22
OFF
START input open
START P. input open
STOP input open
PHOTO input open
operational limits