Proper Use

The devices are safety switching devices. They must only be used as components of safety equipment on machines intended to protect persons, material and
plant.
Notes
The Performance Level (PL) and safety category in accordance with EN ISO 13849-1 depends on the external wiring, the application case, the choice of
control station and how this is physically arranged on the machine.
The user must carry out a risk assessment in accordance with ISO 14121-1.
The entire system/machine must undergo validation in accordance with the applicable standards on the basis of this.
In order for the specified Performance Level (PL) to be achieved, an average annual number of switching cycles must not be exceeded (see EN ISO
13849-1, C.2.4 and Tab. K.1), taking into account the prevailing device load (see EN ISO 13849-1, Tab. C.1) and the application case. Assuming that the
B
value for the maximum load is 400,000, this results in a maximum cycle number of 400,000 / 0.1 x 30 = 133,333 switching cycles/year.
10d
Operating the device not within the specifications may lead to malfunctions or the destruction of the device.
The supply input A1 also serves as a control input. This may lead to short disruptions or a lowering below the operating voltage in order to
switch to the release path.
The indicated times must be observed when the device is operated, otherwise the device could lock. Locking can be cancelled by opening the
safety inputs properly.
SNE expansion devices or external contactors with positively driven contacts can be used to duplicate the enabling current paths.
The device and the contacts must be protected at max. 6 A utilization category gG.
The devices are equipped with overload protection (for short-circuit). After the malfunction has been dealt with, the device is operational again
in approx. 3 s.
Control output S11 is exclusively for connecting control devices as defined in the operating instructions and not for connecting external con-
sumers such as lamps, relays or contactors.
The devices must be installed in a cabinet with a protection class of at least IP 54.
Function diagram for manual start SNO 4062K / KM (Installation 1, 2, 3, 4, 5, 8)
t
t
M
A1
Function diagram for automatic start SNO 4062KM (Installation 6, 7)
t
t
<t
SP
A2
TP
t
= lock time, t
= operate time 1, t
SP
A1
t
= on time, t
= release time 1, t
M
R1
t
t
t
R1
M
A1
t
W
t
t
t
ASP
SP
A2
t
W
t
R1
= operate time 2, t
= test pulse time, t
A2
TP
= release time 2, t
= recovery time
R2
W
A1
S12
S31/S22
S34
K1, K2
13/14, 23/24
31/32
t
R2
= operate time for lock,
ASP
A1
S12
S31/S22
Lock (internal)
K1, K2
13/14, 23/24
31/32