Commissioning/start-up

NOTE
The unit will be destroyed if it is operated with a dimmer. It contains sensitive electrical compo-
nents.
Do not connect the unit to a dimmable power supply.
NOTE
Never allow the pump to run dry. Otherwise the pump may be destroyed.
Only operate the pump when it is submerged or flooded.

Switching ON/OFF

• Switching on: Plug the power plug into the outlet.
– The unit switches on immediately.
• Switching off: Pull the power plug from the outlet.
Environmental Function Control (EFC)
When started up and then every 20 ... 40 minutes the pump automatically performs a pre-pro-
grammed self-test (Environmental Function Control (EFC)). The pump detects if it is running dry
/ clogged or submerged. The pump shuts down automatically after 60 to 120 seconds if it runs
dry/is blocked. In the event of a malfunction, disconnect the power supply and "flood the pump"
or remove the obstacle. Afterwards, the unit can be restarted.