I
I
EN
35 e 40 –MACHINE OVERHEATED
EN
Probable cause: the machine overcomes its maximum working
temperature in the last welding
DE
DE
Solution: Wait until the machine has cooled off.
F
F
45 – CURRENT EXCEEDS MAXIMUM LIMIT
E
E
Probable cause: The heating wires inside the coupler made a
short circuit
P
P
Probable cause: The coupler diameter is bigger than allowed
Solution: Repeat the welding with another coupler
CZ
CZ
50 – CURRENT BELOW MINIMUM VALUE
RO
RO
Probable cause: One or both welding cables were unplugged
during the welding
H
H
Solution: Reconnect the welding cables and repeat the
procedure
EE
EE
Probable cause: The heating wires inside the coupler are
interrupted
RU
RU
Solution: Repeat the welding with another coupler
Probable cause: The coupler is too small (the electrical
RU R
NL
resistance is too high)
Solution: Repeat the welding with a compatible coupler
RU
عر
عر
55 – WELDING CYCLE ABORTED BY THE OPERATOR
ب ي
ب ي
Probable cause: The operator pressed the STOP push button
Solution: Repeat the welding
60 – SHORT CIRCUIT
Probable cause: The coupler is damaged
Solution: Repeat the welding with another coupler
65 – LACK OF VOLTAGE AT THE POWER SOURCE
Probable cause: Power supply cable unplugged
Solution: Plug the power supply cable
Probable cause: The voltage supply was interrupted
Solution: Wait until the service is restored
Probable cause: The safety micro switch has pop out
Solution: Engage the safety micro switch
70 –HARDWARE ERROR
Solution: Contact an authorized service center
75 – COUPLER RESISTANCE ERROR
Solution: Repeat the welding with another coupler
80 – OVERHAUL EXPIRED
Solution: Contact an authorized service center
85 – REPORT MEMORY FULL
Solution: download all the welding data reports stored in the
machine.
Type in OTHER FUNCTIONS the code on page 19 to delete the
stored reports.
If you do not delete the reports and continue to
use the machine, the last report will replace the first one in the
memory, then the second report will be replaced, and so forth.
90 – UNSTABLE CURRENT WITHDRAWAL BY THE COUPLER
Probable cause: The coupler coils can be damaged, or the
cable leads can be loose.
Solution: check the leads and try to replace the coupler. This
error does not appear in the very beginning of the welding
cycle.
100 – HARDWARE ERROR WHEN WELDING STARTS
Probable cause: The coupler coils can be damaged or the
cable, leads can be lose/damaged.
Solution: check the leads and try to replace the coupler. This
error only appears in the very beginning of the welding cycle.
20
110 – POWER OVERLOAD
Probable cause: the fitting requires too much power.
Solution: Use a fitting that requires less power.
8.
MAINTENANCE
Clean the louvers and filter with an air gun
Replacement of worn-out leads.
The specifications of the device and the data
entered in this manual are subject to change without notice
from the manufacturer.
Reproduction of this manual, including in part, is
prohibited.
Full parts lists and technical documents are available online at
www.ritmo.cloud.
Help in the event of problems:
S.p.A.
via A. Volta, 35/37 - Z.I. Selve
35037 BRESSEO DI TEOLO (PD)
ITALY
Tel. +39.049.990.1888
Fax +39.049.990.1993
service@ritmo.it
DISPOSAL
Do not dispose of in the household trash. Add the device
that is no longer able to be used to a separate collection
for the purpose of environmentally friendly recycling.
Contact Ritmo S.p.A. for further info.