Installation
6
Adjust Temperature with Water Running
This valve is NOT factory preset.
Upon installation, the temperature
of this valve must be checked and
adjusted to ensure delivery of a
safe water temperature. Water
in excess of 110°F (43°C) may
cause scalding.
7
Access Panel
Make all connections before installing access panel. Combined
waste arms to be cut in field to accommodate rough in location.
Shown with WashBar Duo. Verge Soap and Faucet similar.
Bradley • 215-1900 Rev. C: ECO 20-08-028B
A
Loosen Cap Screw about ¹⁄₄" (4-6 turns)
and lift up cover (do not remove).
Using cover, turn cartridge gently until
B
desired water temperature is reached.
Do not turn past stops as this may
damage unit. Push cover down and
tighten screw.
H
Hang the access panel onto
A
the access panel bracket as
shown, and then secure the
access panel with the thumb
screw provided.
1/21/2021
GLX-1 / TLX-1
C
19