Time and date setting

Below are given the steps for accessing the relative menu.
MENU
USER
MANUFACTURER'S
TECHNICIAN
Press the key
"access menu" to
access the
MENU page
DATE – TIME
ENABLE EXT. T.
SEASON
CONTRAST
FW VERSION
LANGUAGE
ADJUST
Press the key
"confirm" to
access the
SETUP
page
Loading the auger
Carry out this operation to facilitate the first start-up phases of the stove; Also check that pellets have been fed into the tank and wait for the
stove to reach the "SHUTDOWN" or "FINAL CLEANING" status. The the number expressed in seconds indicates the rotation time of the
infeed screw during the first loading cycle. After this time, the infeed screw stops immediately and then pellets are emptied from the grate
before turning on the equipment.
Below are given the steps for accessing the relative menu.
MENU
USER
MANUFACTURER'S
TECHNICIAN
Press the key
"access menu" to
access the
MENU page
At the end of the auger loading, the display shows 0 "and automatically switches to the USER menu page.
Press the key for several times until the Stand-by page is displayed.
UNLIKE THE MODELS PROVIDED WITH AUTOMATIC CLEANING DEVICE, IN THIS CASE ALWAYS REMEMBER TO EMPTY THE
GRATE BEFORE TURNING ON THE STOVE AND CHECK THAT ALL ITS HOLES ARE FREE OF OBSTRUCTIONS. NEVER EMPTY
THE GRATE INTO THE HOPPER. FIRE HAZARD.
Use and maintenance manual RBH 150 V- RBH 200 V
Press the key
"confirm"
to access the
USER page
Press the key
"confirm"
to access the
page DATE-TIME
Press the key
"confirm"
to access the
USER page
USER
POWER SETTING
CHRONOTHERMOSTAT
SCREW LOADING
SET AIR-PELLET
Press the key "selection" for
Press the increase key to change every single value
Press the increase key to change every single value
Press "confirm" to confirm the settings and switch to the next option.
By pressing the key "back" for several times you will display the
stand-by page.
USER
POWER SETTING
CHRONOTHERMOSTAT
SCREW LOADING
SET AIR-PELLET
rotation of the infeed screw
Page 75
POWER SELECTION
several times
to go to the second
page of the USER menu
and select
SETTINGS.
SCREW LOADING
Press the key
"confirm" to enable the
Rev.1 14/02/18