Ravelli RBH 150 V Manual De Uso página 80

Ocultar thumbs Ver también para RBH 150 V:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Rev.1 14/02/18
Pag.80
EN
Stove State
Below are given the steps for accessing the relative menu starting from Stand-By mode.
MENU
USER
MANUFACTURER'S
TECHNICIAN
Press the key
"access menu" to
access the
MENU page
STOVE STATE
ACTIVE PARTS
ACTUAL STATES
STATE TEMPERATURE
H20 TEMPERATURE
PUMP
3-WAY VALVE HEAT
PRESSURE 1.1 BAR
SHUTDOWN
In this mode you can check the proper operation of the most important parameters of the appliance. Here is a list of real data of the
stove useful for service during inspection.
- Circulator state (ON running)
- Position of 3-way valve DHW (domestic hot water) or HEAT (heating);
- System pressure;
- Stove state;
- Temperature read by the handheld unit;
- External thermostat (request ON);
- Flame temperature (combustion chamber);
- Combustion fume exhaust temperature;
- Inlet flow meter temperature;
- Heated flow meter temp.;
- Electronic board temperature;
To exit the STOVE STATE page and return to Stand-by page, press the button repeatedly.
Settings
Below are given the steps for accessing the relative menu starting from Stand-By mode.
MENU
USER
MANUFACTURER'S
TECHNICIAN
Press the key
"access menu" to
access the
MENU page
After following the procedure above step by step, you can set the following functions:
Use and maintenance manual RBH 150 V- RBH 200 V
Press the key
"confirm"
to access the
USER page
STOVE STATE
ACTIVE PARTS
ACTUAL STATES
STATE TEMPERATURE
H20 TEMPERATURE
POWER MOD
Press the key
"confirm"
to access the
USER page
USER
POWER SETTING
CHRONOTHERMOSTAT
SCREW LOADING
SET AIR-PELLET
to quickly switch to
Stove STATUS.
STOVE STATE
ACTIVE PARTS
ACTUAL STATES
STATE TEMPERATURE
v
HH T ...
EXT.T ...
FLAME T 340°C
FUME T 120°C
F. EX. T 30°C
C. EX. T
55°C
EL B. T---25°C
- Current boiler power;
- Flow read by the flow meter;
- Fume extractor speed;
- Actual flow set;
- Boiler water temperature (SUPPLY);
- Boiler water temperature (optional) - RETURN from the system;
- Boiler DHW temperature;
- Puffer temperature - average warm point;
- Puffer temperature second reading (low temp.).
USER
POWER SETTING
CHRONOTHERMOSTAT
SCREW LOADING
SET AIR-PELLET
"selection" to switch to
second menu page
USER
STOVE STATE
COMFROT CLIMA
SETTING
Press the key
several times
STOVE STATE
ACTIVE PARTS
ACTUAL STATES
STATE TEMPERATURE
H20 TEMPERATURE
T. CALDERA
T.PUFFER H
T.PUFFER L
USER
STOVE STATE
COMFROT CLIMA
SETTING
Press the key
to the function
SETTINGS.