OPERATION
RECOIL START (GEN-4000-0MM1 AND GEN-6500-0MM1)
NOTE: Read Operator's Manual carefully before operating this unit.
Always make sure the unit is level and properly grounded. Check
engine oil before starting.
1. Isolate the generator from the utility
2. Unplug any electrical devices from the receptacles.
3. Turn the fuel switch to the on "I" position.
4. Turn the AC circuit breakers to the off "0" position (CSA models only).
5. If the engine is cold, pull out the choke knob.
6. Turn the generator switch to the on "I" position.
7. Slowly pull the starter handle until resistance is felt, then quickly pull the
starter handle the rest of the way. If the engine does not start, repeat
step 7 until the engine does start.
8. Make sure the generator is grounded. See Preparing the Generator;
Grounding Instructions.
9. Test the GFCI receptacle(s) on the unit. Push the test button. The reset
button should pop out and there should be no power at the receptacle.
Apply a test load or lamp to each receptacle to verify. IF THE RESET
BUTTON DOES NOT POP OUT, DO NOT USE THE RECEPTACLES(S).
SEE DEALER FOR SERVICE IMMEDIATELY.
10. If GFCI receptacle(s) test correctly, firmly push the resetbutton to restore
power. A distinctive click should beheard or felt when this is complete.
IF THE RECEPTACLE(S) DO NOT RESET PROPERLY, DO NOT USE
THE RECEPTACLE(S). SEE DEALER FOR SERVICE IMMEDIATELY.
11. After the engine has warmed, push in the choke knob.
12. Turn the AC circuit breaker to the on "I" position.
NOTE: This engine is equipped with a "Low Oil" shutdown system
for engine protection. The engine stops when the oil level gets
too low. The engine will not restart without adding oil. Refer to
Preparing the Generator; Engine Fuel Capacity for instructions
on adding oil.
ELECTRIC START (GEN-8000-0MM1E)
NOTE: Read Operator's Manual carefully before operating this unit.
Always make sure the unit is level and properly grounded. Check
engine oil before starting.
1. Isolate the generator from the utility.
2.
Unplug any electrical devices from the receptacles.
3. Turn the fuel switch to the on "I" position.
4. Turn the AC circuit breakers to the off "0" position (CSA models only).
5. If the engine is cold, pull out the choke knob.
6. Turn the generator switch to the start position " " and hold it there until
the engine starts.
NOTE: Do not hold the generator switch in the start position " " for
more than 5 seconds. Holding the generator switch in the start
position " " for more than 5 seconds will damage the starter. If
the engine fails to start, wait 10 seconds before trying again.
7. After starting the engine, immediately release the generator switch so
the switch can automatically return to the on "I" position.
8. After the engine has warmed, push the choke knob in.
9. Turn the AC circuit breaker to the on "I" position.