Descargar Imprimir esta página

T&S EC-3130 Instrucciones De Instalación Y Mantenimiento página 17

Publicidad

3. 从水龙头本体上拆卸调节温度手柄
4. 将水龙头本体从底座上垂直向上拉起,将其从底座上取下。
5. 找到传感器背面的拨码开关组。小心不要损坏外露的小印刷电路板。
6. 将拨码开关设置为下面所述的所需设置
7. 小心地将本体笔直向下重新安装在底座上。
8. 重新安装本体螺丝和手柄
AUTO TIME-OUT ADJUSTMENT (SWITCHES 1-3)
EN
The ChekPoint controller provides six periods to select from for shutting off the water
when the object is left in front of the electronic eye. The time periods to select from
are: 15 seconds, 30 seconds, 45 seconds, 60 seconds, 3 minutes and 20 minutes. The
default setting is 15 seconds.
Note: The chart below indicates the switch positions required for each auto time-out mode.
Auto Time Out Selection
PERIOD
15 seconds
30 seconds
45 seconds
60 seconds
3 minutes
20 minutes
Water Shut Off Delay Selection
PERIOD
1 seconds
10 seconds
15 seconds
30 seconds
WATER SHUT-OFF DELAY ADJUSTMENT (SWITCHES 5 & 6)
The ChekPoint controller provides four periods to select from for shutting off the water
when the object is removed from in front of the electronic eye. The time periods to
select from are: 1 second, 10 seconds, 15 seconds, and 30 seconds. The default setting
is 1 second.
METERING MODE (SWITCH 7)
In metering mode, when activated the faucet will remain on for 15 seconds regardless if an object
is in front of the eye or if it is removed and returned to the front of the eye. After 15 seconds, the
sensor resets for another activation.
SW(1)
SW(2)
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
SW(5)
SW(6)
OFF
OFF
OFF
ON
ON
OFF
ON
ON
WATER SHUT-OFF DELAY
AUTO-FLUSH (SWITCH 4)
SW(3)
The ChekPoint controller off ers the
OFF
option to select the Auto Flush mode
ON
in switch 4 position. When enabled,
OFF
the controller will fl ush the Chek-
ON
OFF
Point faucet every 12 hours for 25-30
ON
seconds when the faucet is not used.
Default setting from the factory is in
the "off " position.
Auto Flush Mode
SW (4)
ON - (Enable)
OFF - (Disable)
17
Metering Mode
SW (7)
ON - (Enable)
OFF - (Disable)

Publicidad

loading