Chapter 7. Ordinary maintenance
7.7. Wiring diagram
Q1
Main switch
QM1
Motor contactor
QV1
Air re-immission valve
QV2
Gas injection airvalve
QV3
Sealing airvalve
7.8. Pneumatic diagram
CV
Vacuum hood
UG
Gas nozzles
BA
Suction pipe union
QV1
Air re-immission valve
QV2
Gas injection airvalve
QV3
Sealing airvalve
7.9. Disassembling, demolition and elimination of residuals
ATTENTION!
All operations about disassembling and demolition must be done by qualified personnel with
mechanical and electrical expertise required to work in security conditions.
Proceed as follows:
1.
disconnect machine from power mains
2.
disassemble components
3.
remove oil from the pump
All wastes must be treared, eliminated or recycled according to their classification and to the procedures in force
established by the laws in force in the country the equipment has been installed.
Chapter 8. Guarantee
8.1. Certificate of guarantee
The guarantee runs for 12 months after the installation date under the conditions set forth on the instruction manual.
Fill in the card with all data requested tear out along the perforations and send in.
8.2. Guarantee conditions
The guarantee runs for 12 months and goes into force on the installation date of the machine. The guarantee covers free
replacement or repair of any parts due todefects arising from faulty material. The repairs or replacement are usually carried
out at the manufactures, with transport or workmanship at buyer's charge. If the repair or replacement is carried out at the
buyer's place, he shall bear the travelling, transfer and workmanship charges. Work under guarantee can be carried out
exclusively by the manufacturer or by the authorized dealer. In order to be entitled to repairs under the guarantee, the
faulty part must be sent for repair or replacement to the manufacturer or his authorized dealer. The return of such repaired
or replaced part will be considered to be the performance of the guarantee. The guarantee is voided:
1. in case of failure to mail the CERTIFICATE OF GUARANTEE, duly filled in and signed, with in 20 days after the date of
purchase.
2. in case of inappropriate installation, power supply, misuse and mishandling by unauthorized persons.
3. in case of changes made to the machine without prior agreement in writing by the manufacturers.
4. if the machine is no longer the property of the first buyer.
MINIPACK-TORRE S.p.A. are legally entitled to decline any responsability for damage to persons or things in case
of inappropriate installation or connection to the power mains or omission of connection to earth or in case of
any mishandling of the machine.
The manufacturers undertake to carry out any variations and changes made necessary by technical and operating
requirements.
All manuals and user guides at all-guides.com
FU1
M1
T1
B1
SE
B1
BG
MP
M1
PV
S
12
Fuse
Vacuum pump motor
Blade transformer
Gas pressure switch
Electronic board
Gas pressure switch
Gas cylinder
Pneumatic membrane
Vacuum pump motor
Vacuum pump
Sensor