Chapter 6. Safety standards
6.1. Warnings
Do not touch the sealing blade (16) immediately after sealing.
Danger of burns due to hot blade.
Do not touch the vacuum pump (23) just after a working cycle.
Possibility of burning due to the high temperature the pump may reach.
USE PROTECTION GLOVES!
Do not seal if the sealing wire is broken.
Replace it immediately.
In case of a power failure during a working cycle when the cover is closed, do not use any tool in order to
force its opening. Wait for the power supply to be restored.
Never use gaseous mixtures in presence of oxygen in a percentage higher than the atmospheric one
(~ 19%).
Chapter 7. Ordinary maintenance
7.1. Precautions for ordinary maintenance interventions
Ordinary maintenance, must be executed by qualified staff appropriately trained.
Before any routine maintenance switch the machine off by acting on the main switch and remove the
plug from the mains socket. Disconnect gas plant.
It is recommended to use protection gloves during maintenance operations!
7.2. Cleaning of the sealing bar
Use a dry cloth to remove any film residue on the sealing bar (16). Carry out this operation just after any sealing cycle.
Residues are still hot and may be easily removed.
7.3. Replacement of the Teflon and the sealing blade
Before replacing teflon and the sealing blade wait for the machine to be properly cooled.
Remove the sealing bar (16) from its seat.
Remove the teflon adhesive tape.
Unscrew the screws fastening the blades to each end of the sealing bar.
Tighten the new blades. Make sure they are tout enough before blocking them.
Use the teflon adhesive tape to cover the sealing blades.
Place the sealing bar into its seat.
7.4. Replacement of the cover gasket
When the cover gasket (17) is worn out, replace it. This will improve the efficiency of the machine and increase its speed
rate. Replacement is very easy. After having removed the gasket which has worn out, clean its seat and insert the new
gasket in a linear way. Make sure its ends are joined. Leave no opening which might prevent the product from being properly
vacuum-packed.
7.5. Cleaning machine
Use a normal wet cloth to clean the plexiglas cover (18).
Never use detergents or solvents which might damage the hood and reduce its transparency as well as its resistance.
Use normal detergents for stainless steel to clean the case and the internal tank.
7.6. Changing the oil and the pump filter
Follow the instructions you can find on the pump manual in order to change the oil and the vacuum pump filter.
However, oils of the VC type shall be used in compliance with the DIN 51506 standards.
It is recommended to use original BUSCH oils of the VM series in compliance with the DIN standards.
The oil you have replaced must be eliminated according to the procedures established by the laws in
force in the country the equipment has been installed.
(20) PLUG FOR OIL DISCHARGE (to completely replace old oil)
(21) OIL FILLING PLUG
(22) VISUAL LEVEL