Starting
Prior to starting, refer to your engine manual for proper starting procedures for your engine type.
1. In a well ventilated outdoor area add fresh, high quality, unleaded gasoline with a pump octane rating of 86 or higher. Do not
overfill. Wipe up spilled fuel before starting the engine.
2. Check engine oil level.
NOTE
There will be a slight amount of oil in the engine from factory testing.
3. Verify the filter screen is in water inlet of pump.
NOTE
Cone side faces out.
4. Connect water source to pump inlet.
NOTE
Water source must provide a minimum of 19 liters per minute at 20 p.s.i.
5. Connect high pressure hose to pump outlet.
6. If applying a chemical or cleaning solution, see "How to apply chemicals and cleaning solvents" section of this manual.
7. Turn water source on.
NOTE
Failure to do so could cause damage to the pump.
8. Start engine.
NOTE
If the engine does not start and grip gun/spray wand firmly with both hands. Expect the gun to kick when
triggered.
9. Depress trigger on gun to start water flow.
NOTE
Stand on a stable surface and grip gun/spray wand firmly with both hands. Expect the gun to kick when
triggered.
10. Release trigger to stop water flow.
11. Adjust spray for the task being performed by changing quick connect nozzle. See "How to use spray wand" section of this
manual.