REPAIR ( CONTINUED )
Replace Power Switch
1.
Turn the pump OFF and disconnect from power.
2
Using a 4mm Hex wrench remove the (2) BHCS and nozzle cover.
3.
Remove the (4) M6 SHCS and electrical cover plate from the motor
housing.
4.
Remove the (1) #10 truss head screw and switch bracket with switch
assembly (see Figure 4).
5.
Unplug the four flag terminals to remove the wires from the switch (see
Figure 4a). Take note of which wire is attached to each blade terminal for
reinstallation.
6.
Install a new switch by reversing the above procedure. Insert the switch
assembly into the junction cavity. Reinstall all components and tighten bolts
securely.