Cabinet
Construction
_To
eliminate the risk of burns or fire by
reaching over heated surface units, do not have cabinet
storage space above the range. If there is cabinet
storage space above range, reduce risk by installing a
range hood that projects horizontally a minimum of 5"
(12.7 cm) beyond the bottom of the cabinet.
Countertop
Preparation
• The cooktop sides of the range fit over the cutout
edge of your countertop.
• If you have a square finish (flat) countertop,
no
countertop
preparation is required. Cooktop sides lay
directly on edge of countertop.
Formed front-edged
countertops
must have molded
edge shaved flat 3/4" (1.9 cm) from each front corner
of opening (Figure 7).
Tile countertops may need trim cut back 3/4"(1.9
cm) from each front corner and/or rounded edge
flattened (Figure 7).
The inlet pressure to the regulator must be at least 1"
(.25 kPa) greater than the regulator manifold pressure
setting. The regulator is set for 4"(10,16 cm) water
column (1.0 kPa) Natural gas manifold pressure; the inlet
pressure must be at least 5"(12.60 cm) water column
(1.25 kPa) Natural gas. For LP/Propane gas, the regulator
must be set for 10"(25,4 cm) water column (2.5 kPa)
manifold pressure; the inlet pressure must be at least
11 "(27,9 cm) water column (2.75 kPa).
The supply line should be equipped with an approved
shutoff valve (see Figure 10). This valve should be located
in the same room as the range and should be in a
location that allows ease of opening and closing. Do not
block access to the shutoff valve. The valve is for turning
on or shutting off gas to the appliance. Open the shutoff
valve in the gas supply line. Wait a few minutes for gas
to move through the gas line.
The gas supply between the shutoff valve and the
regulator may be connected by rigid piping or by A.G.A./
C.G.A.-approved
flexible metallic union-connected
piping where local codes permit use.
311/2,,_ j
(81 cm)
Formed
or tile
countertop
trimmed
%" (1.9 cm) back
at
front
corners
of countertop
(1.9 cm)
opening.
I
Figure 7
• If the existing
cutout
width
is greater
than
30 1/16"
(76,4
cm),
reduce
the
3A" (1.9
cm)
dimension.
Countertop
must
be level,
Place a level on the
countertop,
first side to side, then front to back. If
the countertop
is not level, the range will not be level.
The oven must be level for satisfactory baking results.
Cooktop
sides of range fit over edges of countertop
opening.
The gas supply piping can be through the side wall
of the right cabinet. The right side cabinet is an ideal
location for the main shutoff valve.
Gas Supply-
Installation
When shipped from the factory, this unit is designed
to operate on 4"(10,16 cm) water column (1.0 kPa)
Natural gas manifold pressure. A convertible pressure
regulator is connected to the range manifold and MUST
be connected in series with the gas supply line. To access
the regulator, remove the drawer.
For proper operation,
the maximum inlet pressure to
the regulator should be no more than 14"(35,56 cm) of
water column pressure (3.5 kPa).
PRESSURE REGULATOR L OCATION
Figure 8
Connection
to Pressure
Regulator
The regulator is already installed on the appliance.
Do not make the connection too tight.
The regulator is die cast. Overtightening
may crack the
regulator resulting in a gas leak and possible fire or