English
14.4 Restoring factory settings
If the PIN code is disabled, the user and installer settings are reinitialized:
1- From the PIN code, press
2-
Appears . Press
or
= Factory settings reset .
= Factory settings not reset
3- Press the key
for 5 seconds . The device returns to its initial
configuration and goes back automatically to Auto mode .
The following factory values will be effective:
Settings
Comfort setting temperature
Boost duration
Keypad lock
User settings
Backlighting
Eco mode temperature lowering level
Frost protection temperature
Minimum set of Comfort setting
temperature
Maximum set of Comfort setting
temperature
Maximal Boost duration
Maximum ambient temperature
for the automatic stop of the Boost
Temperature unit
Installer settings
Automatic open window
detection
PIN code protection
Value of the PIN code
Expert settings
Power
Indoor temperature monitoring
.
appears briefly on the display .
to select
.
5 sec.
Factory settings
Operation
19°C
60 min .
Disabled
L3
-3,5°C
7°C
7°C
30°C
60 min .
39°C
°C
Enabled
Disabled
0000
500W
90°C
To exit the expert settings, press
15 . Fitting and connections
15.1 Assembling of the controller on to the towel rails
Important: Before carrying out any connection tasks, cut off the power
supply to the electronic regulator using the circuit breaker or the protection
fuse in the power supply circuit .
Connection tasks must be carried out by a qualified professional installer .
Assembling of the controller on to the towel rails
1- Fitting the joint to the cartridge heater (the cartridge)
Fit the joint (supplied) onto the cartridge heater to ensure that the
latter
fits
snugly
Another
o-ring,
may
be present on the cartrid-
ge at this location, depen-
ding on the manufacturer .
It will in no way hinder
assembly of the product .
Leave
it
in
place .
However,
despite
the
presence of o-ring you
still have to put o-rin-
g(supplied)
in
place .
2- Connecting the electronic regulator to the cartridge heater .
Bring the electronic regulator close to the cartridge heater, in order to
connect the two insulated female Faston lugs (the output contacts) to the
two male lugs on the cartridge . Press the lugs together firmly .
3- Fitting the electronic regulator to the cartridge heater
Fit the regulator to the base of the cartridge heater .
4- Fitting and tightening the electronic regulator onto the cartridge heater .
- 38 -
3 times .
into
the
electronic
Bottom of the towel rails
Existing o-ring
Supplied o'ring
Cod . 1910000000276 - nv04
regulator: