Steady gas flow
Solenoid valve
Replace solenoid
faulty?
valve.
Foreign matter in
Clean solenoid
solenoid valve?
valve.
12. Technical Specifications
Model
Supply voltage:
Open-circuit voltage:
Working voltage, electrode:
Working voltage, TIG:
Current setting range, stepless:
Power input max.:
Max. input current:
100% duty cycle 25 °C TIG / 40 °C TIG:
Max. duty cycle 25 °C TIG / 40 °C TIG:
100% duty cycle 25 °C / 40 °C electrode:
Max. duty cycle 25 °C / 40 °C electrode:
Power factor cos ϕ:
Protection class:
Max. electrode size:
Cooling:
Insulation class
Supply circuit fuse:
Dimensions L x W x H:
Weight
No welding current
Earth cable mak-
Check earth
ing poor contact?
cable for proper
contact.
Control PCB
Contact
faulty?
service centre.
V
V
V
V
A
W
A
A
A
A
A
mm
mm
kg
No function of machine
Supply circuit
fuse blown or
cut-out?
WIG 162 DCsi
230, 1~ 50 Hz)
80
20.2 - 26.4
10.2 - 16.4
5 - 160 A
5.2
22.2
125; 100
160, 50% / 160, 25 %
100 / 90
160, 40 % / 160, 25 %
0.99
IP 21
4
F
F
16 A, time-lag
530 x 275 x 349
14.5
ENGLISH
Replace of
switch on again.
WIG 162 AC/DCsi
230, 1~ 50 Hz)
80
20.2 - 26.4
10.2 - 16.4
5 A...160 A.
5.7
24.7
125 / 100
160, 50 % / 160, 25 %
100 / 90
160, 40 % / 160, 25 %
0.99
IP 21
4
F
F
16 A, time-lag
530 x 275 x 349
16
13