Battery Charging - Ac Connections; Assembly Instructions - DSR INDUSTRIAL Serie Manual Del Usuario

Para baterías de 24-voltios
Ocultar thumbs Ver también para INDUSTRIAL Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7.5
Do not face the battery when making the final connection.
7.6
When disconnecting the charger, always do so in the reverse order of the
connecting procedure and break the first connection while as far away
from the battery as practical.
7.7
A marine (boat) battery must be removed and charged on shore. To
charge it onboard requires equipment specially designed for marine use.
8.

BATTERY CHARGING - AC CONNECTIONS

8.1
This battery charger is for use on nominal 100 - 240
volt circuits.
DANGER – Never alter AC cord or plug provided – if it
does not fit the outlet, have proper outlet installed by a
qualified electrician. Improper connection can result in
a risk of an electric shock.
8.2
Recommended minimum AWG size for extension
cords for battery chargers:
AC input rating,
amperes
At least
0
2
3
4
5
6
8
10
12
14
16
18
a
If the input rating of a charger is given in watts rather than in
amperes, the corresponding ampere rating is to be determined
by dividing the wattage rating by the voltage rating
example:
9.

ASSEMBLY INSTRUCTIONS

No assembly required.
a
But less
25
than
(7.6)
2
18
3
18
4
18
5
18
6
18
8
18
10
18
12
16
14
16
16
16
18
14
20
14
1250 watts/125 volts = 10 amperes
AWG size of cord
Length of cord, feet (m)
50
(15.2)
(30.5)
18
18
18
18
16
16
14
14
12
12
12
12
5
100
150
(45.6)
18
16
16
14
16
14
14
12
14
12
12
10
12
10
10
8
10
8
10
8
8
8
8
6
for