Calibrating the unit
• Calibration range: It is possible to calibrate the unit
by +/- 6 °F.
The black calibration controller protrudes out of
the blue temperature controller. There are 3 fixed
positions in the plus and minus range. Each position
corresponds to approx. 2° F.
NOTE
Do not attempt to go outside the calibration range.
E
1. Push the supplied tool out of the heater holder or you
can use a screwdriver for the calibration.
2. Place the tool in the crevice of the post calibration
knob. With your other hand, hold the temperature
controller in place as you adjust the calibration.
• Measured temperature is too high: Keep the
temperature controller at the set value and move
the calibration knob in the direction of - (minus).
• Measured temperature is too low: Keep the
temperature controller at the set value and move
the calibration knob in the direction of + (plus).
10
HeatUp 25/50/100/150/200/300/400
TROUBLESHOOTING
This appliance has no user serviceable inner parts, or equivalent
Issue
Cause
The water
No mains voltage
does not
heat up.
Unit defective
Water does
Insufficient water
not reach
circulation
the set
Unit is not calibrated
temperature.
The heating capacity of the
unit is not sufficient with
regards to the ambient
temperature or water
volume to be heated up.
CLEANING
If necessary, clean the unit with clear water using a
soft sponge or cloth. Do not not use cleaning agents or
chemical solutions.
WEAR PARTS
The following component is a wear part and are
excluded from the warranty: Suction cups
DISPOSAL
NOTE
Do not dispose of this unit with domestic waste!
For disposal purposes, please use the return system
provided. Render the unit unusable beforehand by
cutting the cables.
SPARE PARTS
The use of original parts from OASE ensures continued
safe and reliable operation of the unit. Please visit our
website for spare parts.
https://www.oase-livingwater.com
- EN -
Solution
Check the mains
voltage.
Replace unit
Check the
temperature
Calibrate the unit
Select a suitable
unit.
11