Startup; Startup Menu; V/F Control Type (P0202 = 0) - WEG CFW500 Serie Manual Del Usuario

Ocultar thumbs Ver también para CFW500 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5.2 STARTUP

The startup is explained in a very simple way, using the programming features with
the existing parameter groups in the menus STARTUP and BASIC.

5.2.1 STARTUP Menu

5.2.1.1 V/f Control Type (P0202 = 0)

Seq
Indication on the Display / Action
1
Monitoring mode.
Press the key ENTER/MENU to enter 1st
level of programming mode.
2
The PARAM group is selected, press the
keys  or  until selecting the STARTUP
group.
3
When the STARTUP group is selected
Press the key ENTER/MENU.
4
If necessary, press ENTER/MENU to
modify the content of "P0202 – Control
Type" for P0202 = 0 (V/f).
5
When the desired value is reached, press
ENTER/MENU to save the modification.
Press the key  for the next parameter.
Figure 5.2: Sequence of the Startup group for V/f control
- English -
Powering up and Startup
Seq
Indication on the Display / Action
6
If necessary, modify the content of "P0401
–Motor Rated Current".
Press the key  for the next parameter.
7
If necessary, modify the content of "P0402 –
Motor Rated Speed".
Press the key  for the next parameter.
8
If necessary, modify the content of "P0403
–Motor Rated Frequency".
Press the key  for the next parameter.
9
To end the Start-up routine, press the Key
BACK/ESC.
To return to the monitoring mode, press the key
BACK/ESC again.
CFW500 | 25

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido