Descargar Imprimir esta página

Beninca BRAINY 24-SW Manual Del Usuario página 21

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 44
The intervention threshold of the anti-crashing device (Encoder) during braking is ad-
SEAR
justed *.
0:Off-1:minimum sensitivity - 99: maximum sensitivity
This parameter is enabled only for motors equipped with Encoder.
The encoder inhibition is regulated near the opening and closing mechanical stop-
tinc
pers.
1: minimum distance – 250: maximum distance
AN INCORRECT SETTING OF THESE PARAMETERS MAY RESULT IN AN HAZARD.
With motors without limit switch and/or encoder it adjusts the sensitivity of the sensor which causes arrest during slowing
phase.
** 1: minimum force/torque - 99: maximum force/torque.
The control unit is equipped with two ant-crash devices, the amperometric sensor (regulated by parameters PMO1/2-PMC1/2-PSO1/2-
PSC1/2) and the encoder (regulated by parameters SEAV and SEAR).
The sensitivity of the amperometric sensor is regulated by default through the Autoset procedure, while the encoder (with the default
set) is activated only when the gate stops completely when it hits an obstacle.
The use of one system at a time is recommended, giving preference to the amperometric sensor, which has a lower response time.
MENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables condominium function.
On: condominium function enabled. The step-by-step impulse or transmitter impulse
IbL
has no effect during the opening phase.
Off: condominium function disabled.
The multi-flat function is enabled or disabled during the TCA counting.
On: the bloc of flat function is enabled. The Step-by-Step signal or the transmitter
ibca
signal has no effect during the TCA counting.
Off: the bloc of flat function is disabled.
Enables or disables rapid closing
On: rapid closure is enabled. With open gate, or in the opening phase, the activation
SCL
of the photocell causes the automatic closure 3sec after the total opening of the gate.
It is activated only with TCA:ON
Off: rapid closing disabled.
Selects the operating mode of the "Step by step button" and of the transmitter.
PP
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Enables or disables pre-blinking.
PRE
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
Enables or disables the inversion stroke function
On: Function enabled. Before each opening manoeuvre the control unit orders a ma-
HAM
noeuvre of 2s in the opposite direction to facilitate the release of the electric lock.
Off: Function disabled.
Enables or disables the block function in opening.
On: Block function enabled. To use only with motors equipped with Limit switch.
Blco
After the intervention of the opening Limit switch the control unit delays arrest by about
0.5s, so to allow a better strike of the shutter on the stop locks.
Off: Block function disabled
Enables or disables the block function in closing.
On: Block function enabled. To use only with motors equipped with Limit switch.
Blcc
After the intervention of the opening Limit switch the control unit delays arrest by about
0.5s, so to allow a better strike of the shutter on the stop locks.
Off: Block function disabled.
Enables or disables start at decreased speed.
SOFT
On: Executes start ups at decreased speed for 2 seconds to then shift to normal speed.
Off: Start at decreased speed not active.
Selects the operating mode of the blinking light during the time TCA
LTCA
On: Blinking light on during TCA
Off: Blinking light off during TCA
* WARNING:
COMPLY WITH REGULATIONS IN FORCE!
LOGIC (LOG)
FUNCTION
0-99-(0%)
1-250-(250)
MEMO
ON-OFF-(Default)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
21
EN

Publicidad

loading

Este manual también es adecuado para:

Brainy 24 +