Some messages that are displayed in case of function anomalies are listed as follows:
Obstacle error motor 1/anti-crushing
Amp1
Obstacle error motor 2/anti-crushing
Amp2
Error, encoder 1/detection of the obstacle
ENC1
Error, encoder 2/detection of the obstacle
ENC2
Motor 1 circuit checking error
Err1
Motor 2 circuit checking error
Err2
error/fault power circuit
Err3
PHOTA photocell checking error
Err4
PHOTC photocell checking error
Err5
Error edge active (during autoset)
Err6
Error active stop (during autoset)
Err7
Error active input (during autoset)
Err8
Motor thermal protection intervention
thrm
TECHNICAL DATA
Contol unit supply
Power supply
Output supply
Maximum motor current
Output supply accessories
Protection level
Operating temp.
Radio receiver
Rolling code transmitters supported
DIAGNOSTICS
One segment of the display is linked to each input. In the event of failure it switches on
according to the following scheme.
CLOSE
N.C. inputs are represented by the vertical segments. N.O. inputs are represented by
the horizontal segments.
The control unit sees the message AMP1 or AMP2 in case of anti-crushing ammeter
sensor intervention.
ERROR MESSAGES
Check presence of obstacles on motor 1 leaf run
Check presence of obstacles on motor 2 leaf run
Check the correct connection of motor 1 encoder to the control unit, that no
obstacles are present along the gate stoke and the encoder operates correctly.
Check the correct connection of motor 2 encoder to the control unit, that no
obstacles are present along the gate stoke and the encoder operates correctly.
Check motor 1 connections
Check motor 2 connections
Request technical assistance and eventually replace control unit.
Check connections, PHOT A photocell alignment or presence of obstacles.
Check connections, PHOTC photocell alignment or presence of obstacles.
In autoset phase, the safety edge has intervened.
In autoset phase, the STOP input has intervened.
In autoset phase a PP/Open/Close input has intervened.
Wait for motor cooling, in case reset does not take place, motor replacement
may be necessary
24 Vdc
100÷250 Vac 50/60 Hz
1/2 motor 24Vdc
5+5 A
24Vdc 500mA max.
IP55
-20°C / +50°C
built in 433,92 MHz confgurabile
64
EN
25