Descargar Imprimir esta página

SOMFY 100 io Manual De Instrucciones página 22

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 34
EN
The procedure to follow to activate or deactivate automatic switch-off of each LED light is identical:
• Press the my and Down buttons simultaneously on the control
point until the LED light comes on then goes out.
- If the LED light comes on then goes out once: the function is
activated.
- If the LED light comes on then goes out twice: the function is
deactivated.
2.3.3. Setting the operating duration
You can configure the operating duration of each LED light before
automatic switch-off.
The default setting is 6 hours.
To alter these settings, for each LED light:
1) Briefly press the my and Down buttons simultaneously on the io
control point.
2) Immediately afterwards, press and hold the my and Down buttons
simultaneously until the LED light comes on then goes out.
• Briefly press the Down button to set the duration to 3 hours.
• Or briefly press the my button to set the duration to 6 hours.
• Or briefly press the Up button to set the duration to 12 hours.
The LED light comes on then goes out.
3) Press the my button until the LED light comes on then goes out.
The new setting has been programmed.
2.4. INSTALLATION TIPS AND ADVICE
2.4.1. Questions about the receiver?
Observations
The LED light does not react at all
when a button is pressed on the
control point
The LED light does not come on.
Poor radio performance.
22
5175297A000_LEAF.TUBE WHITE REC 100200 io.indb 22
5175297A000_LEAF.TUBE WHITE REC 100200 io.indb 22
TUBELITE WHITE RECEIVER 100 io - TUBELITE WHITE RECEIVER 200 io
Possible causes
The control point is not
programmed in the receiver.
The control point batteries are
low.
The control point used is not
compatible with the receiver.
The mains power supply is faulty.
The wiring is incorrect.
The ambient temperature is high
(> 45°C).
The antenna is damaged.
Copyright
2023 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
©
1) 1)
0.5 s
2) 2)
< 2 s
= 3 h 00
= 6 h 00
= 12 h 00
3) 3)
Solutions
Follow the commissioning
procedure (see 2.3.)
Replace the batteries, using
batteries with the same
specifications.
Ensure that the two products are
compatible.
Check the power supply.
Check the wiring (see 2.1.)
Wait for the temperature to cool
down.
Contact the After-Sales service.
27/10/2023 10:00:47
27/10/2023 10:00:47

Publicidad

loading

Este manual también es adecuado para:

200 io