Storage; Transportation; Locating Malfunctions - ENAR M35 AFP-M5 Manual De Instrucciones

Agujas con motor interno
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4.5 STORAGE

Store the vibrating pokers in clean, dry and protected areas when it is not used for long periods.

4.6 TRANSPORTATION

When transporting by vehicles, be sure the equipment is safe against slipping, overturning and
blows.
5

LOCATING MALFUNCTIONS

1
en
The poker does not work
The vibrating poker works
correctly but it overheats
The poker works slowly and it
overheats
The motor is noisier
8
M35 AFP-M5 AFP-M6 AFP-M7 AFP-M8 AFP
MP35 AFP-MP5 AFP-MP6 AFP-MP7 AFP
2
4
1.
Three phase 32 A Plug
2.
Cable to switch 4mm2
3.
Cable to switch 4mm2
4.
Cable to switch 4mm2
5.
Switch
1
6.
Cable to motor 2,5mm2
7.
Cable to motor 2,5mm2
8.
Cable to motor 2,5mm2
9.
Motor
PROBLEM
1.- Verify if there is current.
2.- Plug in bad conditions.
3.- Defective switch.
4.- Connections in bad conditions.
1.- Check the poker is not working out of concrete.
2.- Verify the out voltage of the converter
3.- Bearings in bad conditions or without grease.
1.- Verify the out voltage and frequency of converter.
2.- The poker motor might work with two phases.
3.- Check the specifications of the extension cables.
1.- Bearings are not in good conditions.
5
3
6
8
CAUSE/SOLUTION
9
7
ELECTRIC VIBRATING POKERS

Publicidad

Tabla de contenido
loading