Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The shower system may only be used for bathing, hygienic and body cleaning
purposes.
Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using this product.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the applica-
ble standards.
• The plumbing codes applicable in the respective countries must be oberserved.
• The product is not designed to be used with steam baths!
Thermostatic mixer in conjunction with combination boilers
• If fitting a hand shower remove the water limiter from the shower.
• If the continuous water heater causes any problems, or you have different
water pressures you must install a water limiter to the cold supply, (ordered
separately,article number 97510000).
• Thermostatic mixer Shower: When using the Ecostat with combination boilers, the
Ecostop safety set (#95042000) has to be removed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Centre distance:
Connections G 1/2:
Safety against backflow
The product is exclusively designed for drinking water!
Special information for UK (see page 37)
Fault
Insufficient water
Crossflow, hot water being forced into cold water pipe,
or vice versa, when mixer is closed
Spout temperature does not correspond with tempera-
ture set
Temperature regulation not possible
Shower or spout dripping
Instantaneous heater didn't work with thermostat
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
150 ±12 mm
cold right - hot left
Cause
- Supply pressure inadequate
- Filters are dirty (#96922000)
- Shower filter seal dirty
- Backflow preventers dirty or leaking
- Thermostat has not been adjusted
- Hot water temperature too low
- thermo cartridge calcified
- Dirt or sedimentation on valve seat, shut-off unit dam-
aged
- Ecostop safety set removed. (#95042000)
- Flow limiter in handshower isn't removed
- Filters are dirty
- check valve hasn't moved back
Assembly see page 31
Symbol description
Do not use silicone containing acetic acid!
Safety Function (see page 32)
The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.
Adjustment (see page 32)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the
output differs from the temperature set on the thermostat.
ECOSTOP (see page 33)
Maintenance (see page 33)
• To guarantee the smooth running of the thermostat, it is necessary
from time to time to turn the thermostat from total hot to total cold.
• The mixer is equipped with check valves. The check valves must be
checked regularly according to DIN EN 1717 in accordance with
national or regional regulations (at least once a year).
Operation (see page 34)
Dimensions (see page 35)
Flow diagram (see page 35)
Spare parts (see page 36)
Test certificate (see page 36)
Cleaning
see enclosed brochure
Remedy
- Check water pressure (If a pump has been installed
check to see if the pump is working).
- Clean filter in front of the mixer and on the MTC-
thermo cartridge (#96922000)
- Clean filter seal between shower and hose
- Clean backflow preventers, exchange if necessary
- Adjust thermostat
- Increase hot water temperature to 42 ºC to 65 ºC
- Exchange thermo cartridge
- Clean or exchange shut-off unit
- Remove Ecostop safety set (#95042000)
- Remove flow limiter
- Clean the filter / exchange filter
- Exchange check valves