Vent Blockage Test
After the Laundry Hub is installed, run the Vent Blockage Test function to check if the duct system is
properly installed. Vent Blockage Test automatically detects the status of the ducts and reports any
blockage or problems. Proper ducting can reduce drying time and save energy.
NOTE
The Vent Blockage Test function must run when the dryer is cool. If the dryer warms up after the
installation check, run the Air Fluff cycle for several minutes to reduce its internal temperature.
Running the Vent Blockage Test
1. Make sure the drum is empty, and then close the door. (If there are any clothes or other items in the
drum, the test will not give accurate results.)
2. Tap 
to turn on the Laundry Hub.
3. Tap DRYER, and then tap Options.
4. Turn the Navigation dial to select Vent Blockage Test, and then tap OK. Vent Blockage Test starts
immediately.
-
The test takes about 2 minutes and "Testing" is displayed during the test.
CAUTION
Do not open the door during the test.
NOTE
If you have started other procedures before running Vent Blockage Test, the dryer will not enter the Vent
Blockage Test mode.
5. After 2 minutes, when the test is complete, the results are displayed and the dryer sounds a tone. If
status of the duct system is normal, an alarm triggers with the "No problems detected" message. If the
duct system cannot exhaust properly, the check code appears, and the dryer sounds an alarm tone. For
description about the code, see the "Information codes" section on page 94.
If there are any other problems, an information code appears on the display. For description about the
code, see the "Information codes" section on page 94.
-
To stop or cancel Vent Blockage Test, tap
-
The results remain on the display for about 5 minutes and then automatically turn off. You can turn
the results off immediately by tapping
NOTE
• During or after the test, the internal drum is hot. Use caution to prevent burns. The Vent Blockage Test
function is used to check for problems in the current duct system when the dryer is installed for the first
time.
• If the test result displays check code (the duct system is blocked ), refer to the "Ducting requirements"
section on page 28 and the "Exhaust ducting guide" section, and then take proper measures to correct
any problems. If the test is suspended, it could result in incorrect results. Follow the proper procedures
when testing the dryer.
• Even if the test result is normal ("No problems detected"), the duct system could be blocked slightly.
Properly install all duct work according to the installation instructions in this manual.