Descargar Imprimir esta página

GPI EZ-8 Guía De Solución De Problemas página 5

Ocultar thumbs Ver también para EZ-8:

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING GUIDE ( CONTINUED )
SYMPTOM
Motor runs but does not
pump (continued)
Low flowrate
POSSIBLE CAUSE ( S )
7. System air leak
8. Poor connections or
low voltage
9. Fuel level low
10. Motor running
backwards due to
incorrect polarity
1. Strainer partially
clogged
2. Poor connections or
low voltage
3. Suction pipe clogged
or damaged
4. Fuel tank empty
5. Using off-the-shelf
nozzle
6. System air leak
Figure 1
EN
CORRECTIVE ACTION
7. Tighten all pump fittings and
connections. Inspect suction
pipe for leaks or damage.
8. Make sure electrical
connections are secure.
Check battery voltage.
9. Fill tank.
10. Connect red wire to positive
(+) ungrounded side of battery.
See Figure 1 for correct
gear rotation.
1. Remove pump from tank.
Remove suction pipe from
pump. Inspect and clean
strainer inlet.
2. Make sure electrical
connections are secure.
Also check battery voltage.
3. Remove pump from tank.
Inspect suction pipe. Clean
or replace, as necessary.
4. Fill tank.
5. Factory-supplied manual
nozzle is recommended.
6. Tighten all pump fittings and
connections. Inspect suction
pipe for leaks or damage.
Replace, as necessary.
5

Publicidad

loading