GENERAL SAFETY INSTRUCTIONS ( CONTINUED )
SAFETY WARNINGS
MAINTENANCE
NOTE: This pump is designed for minimum maintenance. The motor bearings
are self-lubricating. Inspect the pump and components regularly for fuel leaks
and make sure the hose and power cord are in good condition. If damaged,
replace before use. Keep the pump exterior clean to help identify leaks.
IMPORTANT: Do not use this pump for water, chemicals or herbicides.
Dispensing any fluid other than those listed in the owner's manual may damage
the pump (see BEFORE YOU BEGIN: Fueling Compatibility Statement at front
of the owner's manual). Use of the pump with unauthorized fluids will void the
warranty.
Inspect and Replace Fuse
Remove fuse from fuse holder and inspect (see Figure 2). If fuse appears blown,
replace.
Figure 2
Clean Strainer
Turn the pump off and disconnect from power. Remove the pump assembly from
tank. Remove the gear coverplate and inspect strainer for damage or clogs (see
Figure 3). Clean the strainer with a soft-bristled brush and solvent. If the strainer
is very dirty, compressed air may be used.
NOTE: The tank mount fitting for this pump is not removable.
Figure 3
Observe precautions against electrical shock when operating
the system. Serious or fatal shock can result from operating
electrical equipment in damp or wet locations.
Observe precautions against electrical shock when servicing
the pump. Always disconnect power before repairing or
To prevent physical injury or property damage, observe
servicing. Never apply electrical power to the system when any
precautions against fire or explosion when dispensing fuel. Do
of the cover plates are removed.
not operate the system in the presence of any source of ignition
including running or hot engines, lighted tobacco products, gas
To ensure safe operation, all fuel transfer systems must be
or electric heaters, or any type of electronic device. A spark can
properly grounded. Proper grounding means a continuous
ignite fuel vapors.
metal-to-metal contact from one component to the next,
including tank, tank mount, pump, meter, filter, hose and nozzle.
Observe precautions against electrical shock when operating
Care should be taken to ensure proper grounding during initial
the system. Serious or fatal shock can result from operating
installation and after any service or repair procedures. For your
electrical equipment in damp or wet locations.
safety, please take a moment to review the warnings below.
Observe precautions against electrical shock when servicing
Inspect external pump wiring regularly to make sure it is
the pump. Always disconnect power before repairing or
correctly connected. To avoid electrical shock, use extra care
servicing. Never apply electrical power to the system when any
when connecting the pump to power.
of the cover plates are removed.
Avoid prolonged skin contact with petroleum fuels. Use
To ensure safe operation, all fuel transfer systems must be
protective goggles, gloves and aprons in case of splashing or
properly grounded. Proper grounding means a continuous
spills. Change saturated clothing and wash skin promptly with
metal-to-metal contact from one component to the next,
soap and water.
including tank, tank mount, pump, meter, filter, hose and nozzle.
Care should be taken to ensure proper grounding during initial
Securely fasten all wetted connections with the proper use
installation and after any service or repair procedures. For your
of O-rings, or pipe sealant and thread tape. Leaking fuel may
cause the potential for fire and explosion.
safety, please take a moment to review the warnings below.
Inspect external pump wiring regularly to make sure it is
Pump models that may be used in aviation refueling
correctly connected. To avoid electrical shock, use extra care
(PO/PX models) are NOT supplied with appropriate hose, nozzle,
when connecting the pump to power.
and suction pipe. These items must meet NFPA 407 guidelines.
Avoid prolonged skin contact with petroleum fuels. Use
protective goggles, gloves and aprons in case of splashing or
For ground-based refueling only. Do not use in or on the
spills. Change saturated clothing and wash skin promptly with
aircraft. For use with aviation gasoline (AVGAS 100LL)
soap and water.
and Jet A. User should consult NFPA 407 Standard for
Aircraft Fuel Servicing for safety requirements during
Securely fasten all wetted connections with the proper use
ground fuel servicing of aircraft using liquid petroleum fuels.
of O-rings, or pipe sealant and thread tape. Leaking fuel may
cause the potential for fire and explosion.
This product has no actual or implied compliance with this
standard.
This pump is provided with an internal auxiliary temperature-
Pump models that may be used in aviation refueling
(PO/PX models) are NOT supplied with appropriate hose, nozzle,
limiting device which automatically shuts off the motor before
and suction pipe. These items must meet NFPA 407 guidelines.
overheating. The pump will turn back on automatically after
cooling if the switch is not in the off position. Turn the switch
OFF and wait 30 minutes to resume normal operation.
For ground-based refueling only. Do not use in or on the
aircraft. For use with aviation gasoline (AVGAS 100LL)
If using solvent to clean pump components or tank, observe
and Jet A. User should consult NFPA 407 Standard for
the solvent manufacturer's recommendations for safe use and
Aircraft Fuel Servicing for safety requirements during
disposal.
ground fuel servicing of aircraft using liquid petroleum fuels.
This product has no actual or implied compliance with this
standard.
This pump is provided with an internal auxiliary temperature-
limiting device which automatically shuts off the motor before
overheating. The pump will turn back on automatically after
cooling if the switch is not in the off position. Turn the switch
OFF and wait 30 minutes to resume normal operation.
If using solvent to clean pump components or tank, observe
the solvent manufacturer's recommendations for safe use and
disposal.