5. If "growing" bubbles appear, there is a
leak. Close LP tank valve immediately and
retighten connections. If leaks cannot
be stopped, do not try to repair. Call for
replacement parts. Order new parts by
giving the serial number, model number
and name of items needed to the Service
Center at 1-435-752-3922.
6. Always close LP tank valve after performing
tank leak test by turning hand wheel
clockwise.
• Do not use appliance until leak checked.
• If you cannot stop a gas leak, immediately
close LP tank valve and call LP gas
supplier or your fire department!
Hose Check
• Before each use, check to see if hoses
are cut or worn. Replace damaged hose
assembly before using appliance. Use
only valve/hose/regulator specified by
manufacturer. See product sheet for hose &
regulator information.
Warning: Never operate the appliance without
the grill grease cup installed under the
appliance. Never use the griddle without the
griddle grease cup installed. See assembly
instructions for proper assembly.
Lighting Instructions
Follow the instructions exactly.
1. Check that all burner control knobs and
the cylinder valve are turned to the "OFF"
position.
2. Turn on the fuel supply by rotating the
cylinder valve knob counter-clockwise to full
open.
3. DO NOT stand with head, body, or arms
over the grill when lighting.
Lighting The Main Burners
1. Make sure all control knobs are in the
"OFF" position.
2. Select the burner to be lit. Push and turn
the control knob of that burner to the
"HIGH" position.
3. If ignition does NOT occur in 5 seconds,
turn control knob to "OFF", wait 5 minutes
8
WARNING
to allow gas to dissipate and repeat lighting
procedure.
4. Repeat steps 2–3 for lighting each burner.
If burner does not ignite, wait 5 minutes,
see "Match Lighting the Main Burners"
section.
5. To turn off, turn each control knob
clockwise until it locks in the "OFF"
position. This does not turn off the gas flow
from the cylinder.
Note: If burner does not light or flame is too
low, you may have spider or other insect
blockage in burner. See "Burner Assembly/
Maintenance" under Proper Care and
Maintenance.
Match Lighting The Main Burners
1. Turn the burner control knobs to "OFF".
2. Place a paper match in the end of the
match lighter. Strike the match and place
through lighting hole in the left hand side of
the grill to approximately 1/2" (1 to 2 cm)
from the burner.
3. Turn on the FAR LEFT burner control knob
to the "HIGH" position. The burner should
light within 5 seconds.
4. If the burner does not light, turn the control
knob to "OFF" and wait 5 minutes for gas
to dissipate and repeat lighting procedure.
5. Once lit, light adjacent burners in sequence
by pressing in and rotating the control knob
to the "HIGH" position.
6. If the burner does not light within the first
few attempts of match lighting, there is
a problem with the gas supply. Turn off
the gas at the burner and cylinder. DO
NOT attempt to operate the grill until
the problem is found and corrected. See
"Trouble Shooting" section of this manual.