Descargar Imprimir esta página

EBARA Ego 2 slim Serie Manual De Instalación Y Operación página 31

Ocultar thumbs Ver también para Ego 2 slim Serie:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 70
To see inputs, outputs and communication functions see chapter 5 Setup and operation. Some of the functions
are available only on Ego 2 (T) slim C.
Available in variant Ego 2 (T) slim U.
Maximum resistance of the closed loop
Only potential-free contact can be connected to this input.
Available in variant Ego 2 (T) slim U/C. U variant pumps only have an anlog 0-10V input. C variant
pumps have three connections that can be used either as inputs or outputs, depending on how we set it.
Input voltage
Output voltage
Module U: ~50 kΩ
Input impedance
Module C: ~100 kΩ
Input sink current
Galvanic isolation
Available in variant Ego 2 (T) slim U/C.
Rated current
Maximum voltage
Maximum power
Only available in variant Ego 2 (T) slim C.
Connector
RJ-45, 10BASE-T, 10 Mbit/s.
-Web server (port 80)
Services
-Software update through web interface.
- Modbusa RTU through TCP/IP
Default IP address
192.168.0.245 (192.168.0.246 for right pump)
LED1
Ethernet
visual
diagnostics
LED2
Electrical properties
Electrical properties
–1 - 32 VDC
When used as input.
0 - 12 VDC
When used as an output. MAX II. 5 mA load on individual output.
Open circuit detection – Max source output impedance < 5kΩ
0.5 mA additional load for most configurations.
0 - 33 mA
Common sink on COM, if used as output.
Voltage 4 kV up to 1 s, 275 V permanent.
3 A
250 VAC, 30 VDC
300 VA
Slowly blinking if module is on. Lights up when the connection is established.
100 Ω
Electrical properties
Electrical properties
30
30

Publicidad

loading