Plasma generator (optional):
① Remove the screws (two).
② Pull out the electrode, remove the plasma generator and repair it.
Humidity sensor: Remove the humidity sensor cable from the electric control board, pull out the humidity sensor and
repair it.
Electronic expansion valve coil: Remove the electronic expansion valve coil cable from the electric control board,
pull out the coil and repair it.
Electronic expansion valve coil
5
Remove the water pump and water level switch cable from the electric control board, ① pull out the drainage
pipe from the chassis outlet, ② loosen the two screws fixing the drain pump mounting base, remove the drain
pump assembly, ③ loosen the screws securing the drain pump, remove the drain pump to repair it, and ④
remove the water level switch to repair it.
Drain
nozzle
Humidity sensor (optional)
Screw (two)
Drain pump assembly
(optional)
Plasma generator (optional)
Electronic expansion valve
① Drainage
pipe
④ Water
level switch
③ Drain
pump
69
Cleaning, Maintenance and After-Sales Service
Electrode
② Screw
(two)
Drain pump assembly
Drain
pump
mounting
base