Maintenance of Oscillation Motor
1
Follow the steps above to remove the panel frame and upper and lower louvers.
2
First loosen the screws (three) to remove the display panel, remove the cable terminal on the oscillation motor, then
disconnect the left and right louver rod and the left and right swing motor rod, and take the swing motor and repair
it.
Left and right
louver rod
Screw
(three)
Display panel
73
Connecting rod
Screw
(two)
Oscillation
Oscillation motor
motor base
Cleaning, Maintenance and After-Sales Service
Crank rod
Left/right swing
motor
(optional)
Up/down
swing motor