Zone Setup of Accessories
Every detector can be assigned to 4 different categories of zones: Home Mode Zone, Single
Delay Zone, Normal Zone and 24hZone. To assign a detector to a zone, open its case and move
its jumpers according to the drawing below:
D0
D3
A.
Home Mode zone
Home Mode zone
When the system is armed in Home Mode, the sensors assigned to the Home zone do not
trigger an alarm. It is recommend to assign motion dectors to the Home zone so that you can
have your system armed in Home Mode when you are home and move inside your home without
triggering any alarm.
Delay zone
An entry and an exit delay can be set. In such case, sensors assigned to the "Delay Zone" will
not trigger an alarm during the time of delay set. For example, if you assign a motion detector
to the Delay zone and you set the Entry/Exit Delay to 30 seconds, the motion detector will not
trigger an alarm within 30 seconds after you enter your home and within 30 seconds before
you leave it so that you can leave and enter your home without triggering an alarm. Refer to
the instructions on page 17 of this manual to learn how to set the entry and exit delay. It is
recommended to assign the Door / Window Contact to the Delay zone.
normal zone
When the system is armed, if a sensor is triggered, the siren rings out. When the system is
disarmed, sensors do not trigger an alarm.
24h zone
Regardless the system is armed or disarmed, sensors assigned to the 24h zone will trigger an
alarm. It is recommended to set smoke detectors, gas detectors and outdoor beam sensors in the
24h zone.
D0
D3
B.
Delay zone
D0
D3
C.
Normal zone
D0
D3
D.
24h zone