All mounting hardware
must be used to secure
the builtqn oven to the
cabinets. Refer to the
builtqn
oven installa-
tion instructions.
208/240 Volt grounded
junction box for builtqn
oven,
This cooktop may be in-
stalled over certain built-
in electric oven models.
Approx. 3"
(7.6 cm)
4 1/2" Max. *
(11.4 cm Max.*)
Side filler panels are necessary to isolate the
unit from adjoining cabinets. Panel height
should allow for installation of approved
cooktop models. See "Typical Gas Cooktop In-
stallation Over an Electric Builtqn Oven Installed
Under the Counter" in this booklet.
32" Min.**
(81.3 cm Min.**)
36" Min.
/_
(91.4 cm Min.)
Use 3A" (1.9 cm) plywood, installed on two
runners, flush with toe plate. Must be capable
of supporting 150 Ibs (68 kg).
Cut an opening in wood base mini-
mum 9" x 9" (22.9 cm X 22.9 cm),
2" (5.1 cm) from left side filler
panel, to route armoured cable to
junction box.
*
If no cooktop is installed directly over
the oven unit, 5" (!2.7 cm) maximum
is allowed.
** 32" (8! .3 cm) rain. from top of cabinet
to top of runners must be maintained.
CUTOUT
DIMENSIONS
MODEL'
E, HEIGHT
I
F, WIDTH'
G. DEPTH
27" (68,6 cm)
28 I/8" (71 4 cm) Min
247/8" (63,2 cm) Min
23 1A"(59 7 cm)
Wall Oven
28 Vg" (72,7 cm) Max
25 V4" (64,1 cm) Max
30" (76,2 cm)
28 _¼" (71 8 cm) Min
28 Vz" (72,4 cm) Min
Wall Oven
28718`` (7:3.3 crn) Max.
29" (7:3.7 crn) Max.
24" (61 crn)
Figure 4 - TYPICAL UNDER COUNTER INSTALLATION OF AN ELECTRIC BUILT-IN OVEN
WITH COOKTOP MOUNTED ABOVE