MODEL
INPUT PARAMETERS
Nominal DC Power [kW]
Max. Recommended DC Power [kW]
Operating Input Voltage Range [V]
Full Power MPPT input voltage range (symmetrical load) [V]
Full Power MPPT input voltage range (asymmetrical load) [V]
Absolute Max. Input Voltage [V]
Activation voltage "Vstart" [V]
No of independent MPPT trackers
Max. Input Power, each MPPT [kW]
No. of DC Inputs
Max. DC Current, each MPPT [A]
Absolute Max. input short circuit current (ISC) [A]
DC Connection
Max. inverter Backfeed Current to the array [A]
INPUT PROTECTION
Reverse polarity protection
Fuse rating, each input (-FS suffix versions only) [A]
DC side varistors
PV array Insulation Control
DC Switch (-S/-FS suffix versions only)
OUTPUT PARAMETERS
Nominal AC Power [up to 50°C, kW]
Max. AC Power [kW]
AC Grid Connection
Nominal AC Voltage [V]
AC Voltage Range [V]
Nominal AC Frequency [Hz]
AC Frequency Range [Hz]
Max. AC Line Current [A]
Maximum output fault current (a.c. A, peak and duration or RMS)
AC Connection
Line Power Factor
Inrush Current (a.c. A, peak and duration)
AC Current Distortion [THD%]
OUTPUT PROTECTION
AC side varistors
Ground fault protection (AC + DC leakage current)
ENVIRONMENTAL PARAMETERS
Cooling
Ambient Temp. Range [°C]
Opertaing Altitude [m]
Acoustical Noise [dBA]
Environmental IP Rating
Relative Humidity
Environmental pollution classification for external enviroment
MECHANICAL
BOX Dimensions [H x W x D]
Overall Dimensions (with flanges) [H x W x D]
Weight [kg]
Protective Class
Overvoltage Category in accordance with IEC 62109-1
(*) Limited to 4600W for Germany.
Photovoltaic Inverters
PVI-5000-TL-OUTD
4,8
5,75
150-530
220-530 (@ 4kW) / 90-530 (@ 0,8kW)
200 nominal (adjustable within the range 120Vdc-350Vdc, independently/each input)
8 x Weidmüller / Multicontact Ø 4mm (4 male - positive input + 4 female - negative input); mating cable connector included
Conductor cross section: 4-6mm2 (AWG12-10)
Cable Ø w/insulator: 5,5-9mm (Multicontact), 5,5-7,5mm (Weidmüller)
NA
4 ( 2 for each MPPT ), thermally protected
5(*)
5(*)
180-264 (may vary to comply with regulations in each country)
47-53 (may vary to comply with regulations in each country)
25 (32 short circuit)
Conductor Cross Section: Solid: 0,5-16mmq / Stranded: 0,5-10mmq / AWG20-6
Cable Gland: M32 - Cable Ø: 13-21mm
<3,5% at rated power with sine wave voltage
-25 / +60 (output power derating above 60 °C)
7 - APP
PVI-6000-TL-OUTD
0,7xVstart - 580
220-530 (@ 4kW) / 120-530 (@ 2,2kW)
600
2
4
4 (2 each MPPT)
18
22
Negligible
Yes
according to local standard
Integrated (Rating: 600Vdc / 25Adc)
single phase 230Vac 50Hz + PE
230
50
30 (40 short circuit)
<40 A rms (100ms)
Cage-clamp terminal block
>0,995
Negligible
2, plus gas arrester to ground
according to local standard
Natural cooling
-25 / +60 (output power derating above 50 °C)
2000
<50 @1mt
IP65
0-100% condensing
3
740 x 325 x 208
910 x 325 x 222
26
I
II (DC Input); III (AC Output)
6,2
6,9
180-530
NA
6
6